Knowde Enhanced TDS
Identification & Functionality
- Plastics & Elastomers Functions
- Technologies
Features & Benefits
- Benefits
Cross-linking ETFE increases mechanical properties such as scrape abrasion, cut-through resistance, and tensile strength, especially at elevated temperatures. Flammability of the cross-linked polymer is also improved.
Applications & Uses
- Markets
- Plastics & Elastomers Processing Methods
Properties
- Physical Form
- Typical Physical Properties
Value | Units | Test Method / Conditions | |
Bulk Density | 880 | grams/liter | ASTM D-1895 |
Dielectric Constant (at 1mHz, 23°C) | 2.6 | — | ASTM D-150 |
Dielectric Loss Tangent (at 23°C,1mHz) | 0.0007 | — | ASTM D-150 |
Elongation | 400 | % | ASTM D-638 |
Melt Flow Rate | 11 | g/10 min | ASTM D-3159 |
Melt Point | 258 | °C | ASTM D-3159 |
Tensile Strength | 52 | MPa | ASTM D-638 |
Volume Resistivity | min. 10¹⁷ | Ω-cm | ASTM D-257 |
Regulatory & Compliance
- Hazardous Substances
- This product does not contain lead, hexavalent chromium, or cadmium, and are used in applications where RoHS (Restrictions on the use of Certain Hazardous Substances) compliance is required.
Technical Details & Test Data
- Processing
This ready-to-use product can be processed using conventional thermoplastic techniques such as compression and injection molding and melt extrusion under standard ETFE operating conditions.
The processed article can be cross-linked using electron-beam radiation or gamma radiation.
It is strongly recommended that process equipment exposed to molten resin be made of corrosion-resistant metals such as Monel, Inconel, or Hastelloy.
Safety & Health
- Safe Handling Information
A summary of the hazards, as defined by OSHA Hazard Communication Standard, 29 CFR 1910.1200 for this product are:
Physical hazards: None
Health hazards: NoneFOR ADDITIONAL INFORMATION AND HANDLING INSTRUCTIONS READ AGC CHEMICALS AMERICAS, INC. MATERIAL SAFETY DATA SHEET.
Packaging & Availability
- Packaging
- Fluon+ FP-E-93000 XL NATURAL LF is packed in polyethylene bags in fiber drums each containing 225 pounds or a plastic pail containing 10 kilograms.
Storage & Handling
- Handling Precautions
Heating Fluon® and Fluon+™ products in excess of 750°F (399°C) can produce toxic fumes. It is, therefore, necessary to provide local exhaust ventilation in areas where Fluon® products are exposed to high temperatures. Avoid breathing fumes or contaminating smoking tobacco with fumes, powder, or dust.