Knowde Enhanced TDS
Identification & Functionality
- Chemical Name
- CASE Ingredients Functions
- CAS No.
- 13048-33-4
- EC No.
- 235-921-9
- Technologies
- Product Families
Features & Benefits
- Performance Highlights
HDDA is characterized by:
- Very low viscosity
- Low color
Efficient reduction of oligomer viscosity UV/EB curable formulated products containing HDDA are characterized by:
- Improved elasticity
- Improved weathering
- Good cure response at low cross-link density
- Improved adhesion
- Good water resistance
The actual properties of UV/EB cured products also depend on the selection of the other formulation components such as oligomers, additives and photoinitiators
Applications & Uses
- Applications
- Compatible Substrates & Surfaces
- Coating Type
- Ink & Toner Type
- Recommended Uses & Known Applications
HDDA is especially useful in UV/EB curable coatings and inks where improved adhesion, increased elasticity and good weathering are desired.
HDDA is recommended for use in:
- Improved adhesion to plastics, metal and glass
- Exterior durable coatings and inks
Properties
- Physical Form
- Appearance
- Clear Liquid
- Physical Properties
- Typical Properties
Value | Units | Test Method / Conditions | |
Density (25°C) | 1.02 | g/ml | — |
Flash Point | min. 100 | °C | — |
Formula Weight | 226 | — | — |
Value | Units | Test Method / Conditions | |
Viscosity (25°C) | 44778 | cP/mPa·s | — |
Acid Value | max. 0.4 | mg KOH/g | — |
Color (Pt-Co scale) | max. 40 | — | — |
Residual Solvent Content | max. 0.09 | wt. % | — |
Water Content | max. 0.1 | wt. % | — |
Safety & Health
- Precautions
Before using HDDA, see the Safety Data Sheet (SDS) for information on the identified hazards of the material and the recommended personal protective equipment and procedures.
Storage & Handling
- Storage and Handling
- Care should be taken not to expose the product to high temperature conditions, direct sunlight, ignition sources, oxidizing agents, alkalis or acids. This might cause uncontrollable polymerization of the product with the generation of heat. Storage and handling should be in stainless steel, amber glass, amber polyethylene or baked phenolic lined containers. Procedures that remove or displace oxygen from the material should be avoided. Do not store this material under an oxygen free atmosphere. Dry air is recommended to displace material removed from the container. Wash thoroughly after handling. Keep container tightly closed. Use with adequate ventilation.
- See the SDS for the recommended storage temperature range for HDDA.