Popular DuPont Products
View All DuPont ProductsKnowde Enhanced TDS
Identification & Functionality
Kalrez® 8002 Features & Benefits
• Ultra-low particle generation in oxygen and fluorine-based plasmas
• Excellent (low) compression set properties
• Excellent plasma-cracking resistance
• Excellent resistance to dry process chemistry
Kalrez® 8002 has been reported to significantly improve wafer production in a variety of semiconductor ash process applications where oxygen and fluorinated plasmas are used.
Case Report #7737 - Kalrez® 8002 Improved Wafer Production Over 5x versus Incumbent Perfluoroelastomer
• Process Type: Ash • Process chemistry: O2, CF4
• Process Temperature: ~80C
• Cleaning chemistry: N/A
• Incumbent Performance: Perfluoroelastomer failed after 270 RF hours due to cracking and vacuum leakage.
Case Report #4536 - Kalrez® 8002 Improved Wafer Production Over 50% versus Incumbent Perfluoroelastomer
• Process Type: Ash top/bottom plasma tube seals
• Process chemistry: O2, CF4
• Process Temperature: 80-150C • Cleaning chemistry: N/A
• Incumbent Performance: Perfluoroelastomer failed due to erosion and excessive particle generation after 6 months
Competitive FFKM A11 and Kalrez® 8002 after comparable life cycles in the same process
Applications & Uses
• Gas inlet seals
• Gas orifice seals
• Gas feedthrough seals
• "Select" bonded door seals
• Other static and low stress/low sealing force applications
Properties
Value | Units | Test Method / Conditions | |
Modulus (at 100% Elongation) | 2.3 | MPa | ASTM D 412 |
Tensile Strength | 23.1 | MPa | ASTM D 412 |
Elongation (at Break) | 256 | % | ASTM D 412 |
Hardness (Shore A) | 69 | - | ASTM D 2240 |
Compression Set (O-Ring AS568-214, at 204°C, 70h) | 12 | % | ASTM D 1414 |
Value | Units | Test Method / Conditions | |
Maximum Service Temperature ¹ | 275 | °C | - |
Value | Units | Test Method / Conditions | |
Coefficient of Linear Thermal Expansion | 3.95 | E-4/°C | ISO 11359-1/-2 |
Retraction Temperature (TR-10) | 1 | °C | ASTM D 1329 |
- [1]: DuPont proprietary test method; useful temperature range may vary with seal design and application specifics