APPROVED FOR HARSH OUTDOOR CONDITIONS
As a global standard solution, Formex™ GK-10 meets all critical flammability and environmental requirements in Europe, North America and Asia. This includes WEEE, RoHS and REACH. It was recently tested by Underwriters Laboratories (UL) for UV stability, water exposure and immersion. Following rigid UL 746C test protocol, UL granted Formex™ GK-10 black electrical insulation material its f1 rating as a certified product for use in outdoor environments. This electrical insulation material is ideal for protecting the delicate components within LED lighting, IP security cameras, access control systems and digital signs-just to name a few.
- Features
- Flammability Rating UL 94 VTM-0
- H20 Absorption 0.06%
- Temperature Rating 115°C / 239°F
- Dielectric Strength 2,200 Volts / mil @0.005"
- UL Recognized File E121855
Applications & Uses
- Applications
Properties
- Flame Rating
- Physical Form
- Mechanical Properties
- Typical Properties
- Electrical Properties
- Flammability
Value | Units | Test Method / Conditions | |
Tensile Yield Machine Direction | 4400 | psi | ASTM D-882 / ISO 527-1,-2 |
Tensile Yield Transverse Direction | 3200 | psi | ASTM D-882 / ISO 527-1,-2 |
Value | Units | Test Method / Conditions | |
Density | 1.035 | g/cc | ASTM D792 / ISO 11831 Method A |
Heat Deflection Temperature under load | 121 / 250 | °C / °F | ASTM D-648 0.45MPa / ISO 75-1,-2,Method B |
Oxygen Index | 29 | % | ASTM D-2863 / ISO 4589--1,-2 |
Surface Energy (as produced) | min. 50 | dynes / cm | ASTM D-2578 |
Thickness inches | 0.010 (+0.003 / -0.0015) | — | — |
Thickness millimeters | 0.25 (+0.08 / -0.04) | — | — |
Water Absorption - % Change in weight | 0.06 | % | ASTM D-570 / ISO 62, Method 4 |
Value | Units | Test Method / Conditions | |
Comparative Tracking Index | 600 | volts | IEC 60112 |
Dielectric Breakdown | 16264 | volts | ASTM D-149 / IEC 60243-1 |
Dielectric Constant | 1.9 | — | ASTM D-150 / IEC 60250, 1MHz |
Dielectric Strength | 1626 | volts / mil | ASTM D-149 / IEC 60243-1 |
Dissipation Factor | 0.0023 | — | ASTM D-150 / IEC 60250, 1MHz |
Volume Resistivity | 3.97 x 10^15 | Ω·cm | ASTM D-257 / IEC 62631-3-1 |
Value | Units | Test Method / Conditions | |
Comparative Tracking Index - PLC | 0 | — | ASTM D-3638 |
Flammability | VTM-0 | — | UL 94 |
High Current Arc Ignition - PLC (arcs to ignite) | 0 | — | UL 746A |
High Voltage Arc Tracking - PLC (in / min) | 0 | — | UL 746A |
Hot Wire Ignition - PLC (seconds) | 0 | — | UL 746A |
Relative Temperature Index Electrical | 115 / 239 | °C / °F | UL 746B |
Relative Temperature Index Mechanical Without Impact | 115 / 239 | °C / °F | UL 746B |
Regulatory & Compliance
- Certifications & Compliance
- Quality Standards
Packaging & Availability
- Packaging Type
- Availability And Technical Specifications
Formex™ GK-10 is currently available in extruded sheets and rolls. Our experienced engineers can help you design Formex™ GK-10 electrical insulation material into a wide variety of shapes to meet your unique requirements.
- Packaging Information
Standard Configuration Roll Core ID - inches (millimeters) 6 (152) Roll OD - inches (millimeters) (approximate) 18 (457) Roll Width - inches (millimeters) 24 (610) Roll Weight - lbs (kgs) (approximate 198 (90) Length/Roll - feet (meters) 2,000 (609.6) Area/Roll - square feet (square meters) 4,000 (371.6) Area/Roll - square feet (square meters) -