Knowde Enhanced TDS
Identification & Functionality
- Reinforcement Material
- Composite Materials Functions
- Technologies
Features & Benefits
- Materials Features
Applications & Uses
- Applications
Properties
- Typical Properties
- Flammability
Value | Units | Test Method / Conditions | |
Rockwell Hardness | 85 | Scale M | ISO 2039-2 |
Flexural modulus | 11 | MPa | ISO 14125A |
Tracking resistance CTI | 600 | V | IEC 112 |
Linear Shrinkage | 0,0 | % | ISO 2577 |
arc resistance | min. 180 | s | ASTM D 495 |
Flexural strength | 120 | MPa | ISO 14125A |
Tensile strength | 40 | MPa | ISO 527-4 |
Tensile Modulus | 10 | MPa | ISO 527-4 |
Impact strength (Charpy) | 60 | KJ/m2 | ISO 179 |
Heat distortion temperature HDT | min. 200 | °C | ISO 75-2 |
Glow wire | 960 | °C | IEC 695-2-1 |
Water absorption | 0,2 | % | ISO 62 Met. 1 |
Density | 1,8 | g/cm3 | ISO 1183 |
Surface resistivity | 10^14 | — | — |
Value | Units | Test Method / Conditions | |
Flammability | V0 (3) | — | — |
Regulatory & Compliance
Storage & Handling
- Handling and Storage
- Storage in a dry place at 15-25°C, out of direct sunlight
- Molding time 30 s/mm
- Molding pressure 76 - 110 bar
- Molding temperature 140 - 160°C