Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Chemical Name
- Base Chemicals Functions
- CAS No.
- 64742-47-8
- EC No.
- 265-149-8
Features & Benefits
- Fluids & Lubricants Features
Applications & Uses
- Markets
- Applications
- Applicable Processes
- Fluids & Lubricants Type
- Base Chemicals End Uses
- Fluids & Lubricants End Use
- Recommended Uses & Known Applications
Sasol Chemicals Sasol 47 Solvent may be used in a wide array of applications including printing ink formulations, consumer products, lubricating oils, chemical process solvents, degreasers and metal rolling oils.
Properties
- Odor
- Mild
- Appearance
- Clear liquid
- Typical Properties
Value | Units | Test Method / Conditions | |
Distillation Range - IBP | 238 – 249 (460 – 480) | °C (°F) | ASTM D-86 |
Distillation Range - 95% | 260 – 282 (500 – 540) | °C (°F) | — |
Normal Paraffin Content | 17 – 25 | wt. % | GC/UV |
Specific Gravity at 16°C (60°F) | 0.800 – 0.825 | — | ASTM D-287 |
Density at 16°C (60°F) | 6.68 – 6.88 | lbs/gal | ASTM D-287 |
Molecular Weight (Average) | 196 | — | API |
Aromatic - BTEX Content | ND* | ppm | EPA 8260B |
Color (Saybolt) | min. 15 | — | ASTM D-156 |
Color | min. 15 | Saybolt | ASTM D-156 |
Relative Evaporative Rate (n-Butyl Acetate = 1) | max. 0.01 | — | ASTM D-3539 |
Vapor Pressure at 20°C (68°F) | max. 0.1 | mmHg | — |
Viscosity at 20°C (68°F) | 3.7 – 3.9 | cSt | ASTM D-445 |
Viscosity at 40°C (104°F) | 2.4 – 2.5 | cSt | ASTM D-445 |
Solubility Parameters | 15.7 | MPa | Calculated |
Sulfur Content | max. 1 | mg/kg | RCM 5202 |
Bromine Number | max. 0.2 | — | ASTM D-1159 |
Total Nitrogen | max. 1 | ppm | — |
Water Content | max. 50 | ppm | Karl-Fischer |
Pour Point | -25 (-13) | °C (°F) | ASTM D-97 |
Kauri-Butanol Value | 27 | — | ASTM D-1133 |
Flash Point | min. 96 (205) | °C (°F) | ASTM D-93 |
Aniline Point | 81 (178) | °C (°F) | ASTM D-611 |
Regulatory & Compliance
Packaging & Availability
- Regional Availability
Storage & Handling
- Storage And Handling
Safe handling advice
- Ensure all equipment is electrically grounded before beginning transfer operations.
Storage/Transport pressure
- Ambient
Load/Unload temperature
- min. 0°F Avoid unneeded heating.