SHD Composites FR308

Shanghai Sunwise Chemical FR308 prepreg is a flame retardant resin system meeting the flame, smoke and toxicity requirements of aerospace standard CS 25.853 and rail standard EN 45545. It can be supplied on a variety of fabrics to meet your cost and manufacturing requirements. This resin system color is dark brown / black.

Functions: Prepreg

Processing Methods: Prepreg Processing

Technical Data Sheet
  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Composite Materials Functions

Features & Benefits

Key Features

• FST properties:

         CS 25.853 compliant (Heat Release < 25kW/m2 ) 

         EN 45545 compliant, rated HL3

• Cure temperature from 120°C

• Service temperature up to 170°C after post cure*

• Work life at 20°C: 21 days

• Storage life at -18°C: 12 months

• *Capable of exposure to higher temperatures

Applications & Uses

Composites Processing Methods
Typical Applications

Aerospace / Rail / Flame retardant

Properties

Typical Properties
ValueUnitsTest Method / Conditions
Cure Temperature120 - 140°C
Cure Time1.5 - 1hrs,mins
Outlife21months
Tg Onset175
Tg Peak240
Service Temperature170°C

Technical Details & Test Data

Cure Cycles and Performances
Cure Post cure Post cure Post cure Service Temperature Tg – E’ Onset Tg – tan δ Peak
120°C 90 min      -      - 120°C 125°C 170°C
130°C 1 hour      -      - 150°C 160°C 200°C
130°C 1 hour 150°C 3 hours 170°C 175°C 240°C

Recommended cures:

   • Autoclave / Oven cure o 130°C for 1h, at a ramp rate of 2-3°C/min o P3 Release film recommended

   • Press cure o 80°C for 15min, at a ramp rate of 2-3°C/min o 130°C for 1h, at a ramp rate of 2-3°C/min o Cool down below 90°C before opening the press

The cures given are as a guide only, and will be subject to changes in part geometry and construction.

Safety & Health

Health And Safety

The following precautions must be taken when using PFA resin prepregs:

• Impervious gloves are recommended.

• To avoid exotherm, particular care must be taken with thick laminates.

• Ramp rates must not exceed 3.0°C/min during initial cure and 1.0°C/min during post cure.

Packaging & Availability

Packaging Type

Storage & Handling

Storage and Out Life

This material should be kept frozen at -18°C for a maximum storage life. If kept refrigerated at 6°C storage life will be reduced to 2 months. It must be kept sealed in a polythene bag which must not be opened until fully thawed to room temperature. If the material is not fully used, then the material must be resealed in the polythene bag to prevent moisture absorption.