SHD Composites FRVC411

Shanghai Sunwise Chemical FRVC411 is a toughened, flame retardant epoxy resin system designed to cure between 65°C and 120°C allowing flexibility in component manufacture. It can be supplied on a variety of fabrics and in UD format to meet your cost and manufacturing requirements. This resin system color is opaque white.

Polymer Name: Epoxy Resins & Compounds

Functions: Prepreg

Processing Methods: Prepreg Processing

Technical Data Sheet

Similar Products

  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Composite Materials Functions

Features & Benefits

Labeling Claims
Key Features
  • Cure temperature from 65°C to 120°C
  • Service temperature up to 150°C after post cure
  • Low CTE and shrinkage
  • Work life at 20°C: 21 days
  • Storage life at -18°C: 12 months
  • Very low VOC content – no added solvents during manufacture
  • FST properties

                   CS 25.853 compliant

                   EN 45545 HL1 – rated HL3 for flame propagation, smoke and toxicity

                   Rated UL94 V0 (0.5mm laminate), UL94 V1 (2mm and 4mm laminates)

Applications & Uses

Composites Processing Methods
Typical Applications

Flame retardant – Aerospace / Rail

Properties

Typical Properties
ValueUnitsTest Method / Conditions
Cure Temperature65 - 120°C
Cure Time16 - 1hrs,mins
Outlife21months
Tg Onset155
Tg Peak176
Service Temperature150°C

Technical Details & Test Data

Cure Cycles and Performances
  • Recommended Initial cure:

                    1 st dwell at 85°C for 15 min, at a ramp rate of 2-3°C/min

                     2 nd dwell at 120°C for 1h, at a ramp rate of 2-3°C/min

  • Recommended Post cure: 150°C for 1h, at a ramp rate of 0.3°C/min (if required to develop Tg)
Cure Initial Min Cure Tg
65°C (minimum) 16 hours 80°C
80°C 5 hours 90°C
100°C 2 hours 110°C
120°C (maximum) 1 hour 135°C
150°C Post Cure 1 hour 155°C
  • Curing Schedule is meant to be a guide only and is subject to local conditions.
  • To avoid exotherm particular care must be taken with thick laminates.

                Ramp rates must not exceed 3.0°C per minute during initial cure.

                Ramp rates must not exceed 0.3°C per minute during post cure (free standing).

Safety & Health

Health And Safety

This material contains epoxy resin which can cause allergic reactions with skin contact and must avoid repeated and prolonged skin contact.

The following precautions must be taken when using epoxy resin prepregs:

  • Overalls must be worn.
  • Impervious gloves must be worn.
  • Curing schedule is meant to be as a guide only and is subject to local conditions.
  • To avoid exotherm, particular care must be taken with thick laminates.
  • Ramp rates must not exceed 3.0°C/min during initial cure and 0.3°C/min during post cure.

Packaging & Availability

Packaging Type

Storage & Handling

Storage and Out Life

This material should be kept frozen at -18°C. It must be kept sealed in a polythene bag which must not be opened until fully thawed to room temperature. If the material is not fully used, then the material must be resealed in the polythene bag to prevent moisture absorption.