SHD Composites MTFA400

Shanghai Sunwise Chemical MTFA400 resin film is designed to give enhanced toughness and higher service temperature, giving great flexibility in component manufacture. It is a toughened epoxy resin system that can be supplied with or without fabric support to meet your cost and manufacturing requirements.

Chemical Family: Epoxy & Epoxy Derivatives

Functions: Adhesive, Surface Finish

Technical Data Sheet

Similar Products

  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Composite Materials Functions

Features & Benefits

Labeling Claims
Key Features
  • Cure temperature from 80°C to 150°C
  • Service temperature up to 180°C after post cure
  • Low CTE and shrinkage
  • Work life at 20°C: 28 days
  • Storage life at -18°C: 12 months
  • Very low VOC content – no added solvents during manufacture

Applications & Uses

Composites Processing Methods
Typical Applications

Resin film

Properties

Typical Properties
ValueUnitsTest Method / Conditions
Cure Temperature80 - 150°C
Cure Time16 - 1hrs,mins
Outlife28months
Tg Onset179.6
Tg Peak199.4
Service Temperature180°C

Technical Details & Test Data

Cure Cycles and Performances
  • Recommended cure cycle for 150°C service temperature: 150°C for 1h, at a ramp rate of 2.0°C/min

Alternative cures

Cure Initial Min Cure Tg
80°C (minimum) 16 hours 90°C
100°C 4 hours 110°C
120°C 2 hours 130°C
150°C (maximum) 1 hour 160°C
180°C Post Cure 2 hours 190°C
  • Curing Schedule is meant to be a guide only and is subject to local conditions.
  • To avoid exotherm particular care must be taken with thick laminates. It is recommended that small scale trials are carried out before larger cures carried out.

           Ramp rates must not exceed 2.0°C per minute during initial cure.

           Ramp rates must not exceed 0.3°C per minute during post cure (free standing)

Safety & Health

Health And Safety

This material contains epoxy resin which can cause allergic reactions with skin contact and must avoid repeated and prolonged skin contact.

The following precautions must be taken when using epoxy resin prepregs:

  • Overalls must be worn.
  • Impervious gloves must be worn.
  • Curing schedule is meant to be as a guide only and is subject to local conditions.
  • To avoid exotherm, particular care must be taken with thick laminates.
  • Ramp rates must not exceed 3.0°C/min during initial cure and 0.3°C/min during post cure.

Packaging & Availability

Packaging Type

Storage & Handling

Storage and Out Life

This material should be kept frozen at -18°C. It must be kept sealed in a polythene bag which must not be opened until fully thawed to room temperature. If the material is not fully used, then the material must be resealed in the polythene bag to prevent moisture absorption.