MAKON® 8 serves similarly to makon® 12, functioning as a high-active nonionic surfactant with versatile applications. Its use spans agricultural applications, detergents, sanitizers, industrial cleaners, metal cleaners, textiles, and paper deinking. Just like MAKON® 8's counterpart, it holds kosher certification.

Functions: Emulsifier, Surfactant, Surfactant (Nonionic), Wetting Agent

Labeling Claims: Kosher

Certifications & Compliance: Kosher

Applicable Processes: Paper Deinking

Knowde Enhanced TDS

Identification & Functionality

CAS No.
127087-87-0
EC No.
500-315-8
Chemical Structure

MAKON® 8 - Chemical Structure

Surfacant Type

Non-ionic

Surfactant Type

Nonionic.

Features & Benefits

Labeling Claims
Agrochemicals Features
Biodegradability

MAKON 8 is biodegradable.

Applications & Uses

Applicable Processes
Fluids & Lubricants Type
Fluids & Lubricants End Use
Industrial Additives End Use
Applications

MAKON 8 surfactants are nonionic in nature; they neither ionize in water nor hydrolyze in aqueous acid or alkaline solutions. Chemically, they are the reaction products of nonylphenol and ethylene oxide. They differ in the mole ratio of hydrophilic ethylene oxide to hydrophobic nonylphenol. The MAKON surfactants are high active products that offer a broad range of properties. Because of this versatility, MAKON products find application in a number of different industries and in a multitude of products including agricultural emulsions, detergents, sanitizers, industrial cleaners, metal cleaners, textiles, paper de-inking and drilling products.

Properties

Physical Form
Appearance
Clear liquid (at 25°C)
Typical Properties
ValueUnitsTest Method / Conditions
Cloud Point (1% in water)24°C
pH (5% in 1:1 IPA:H₂O)7.5
Actives Content99.8%
Color54Apha Scale
Density1.04g/ml
Freeze Point3°C
Hydroxyl Number95
HLBapprox. 12
Pour Point6°C
Average Number of Moles of Ethylene Oxide8
Viscosity (at 25°C)240cPs
Flash Pointmin. 94°CPMCC Flash Point Tester
Regulated Volatile Organic Chemicals0%U.S. EPA

Regulatory & Compliance

Certifications & Compliance
Clearances
  • MAKON 8 is listed in the following countries; the registration numbers for the active ingredients are included in parentheses: United States (TSCA 127087-87-0), Australia (AICS 127087-87-0), Canada (DSL 127087-87-0), China (IECSC 127087-87-0), Europe (NLP 500-315-8), Japan (ENCS 7-172), Korea (ECL Serial No. KE-26246), New Zealand (NZIoC 127087-87-0), and Philippines (PICCS 127087-87-0). It is the responsibility of the end user to review the chemical control regulations for each country.
  • MAKON 8 is available as Kosher certified.

Safety & Health

Health Effects

MAKON products are slightly to practically non-toxic orally (LD50 > 1400 mg/kg). Undiluted MAKON products are moderately to severely irritating to eyes, while concentrations of 25% or less are minimally irritating to eyes.

Packaging & Availability

Packaging Type
Standard Packaging

MAKON 8 is available in drums (475 lb, 215 kg) and in bulk quantities.

Storage & Handling

Storage & Handling

Normal safety precautions (i.e. gloves and safety goggles) should be employed when handling MAKON surfactants. Contact with the eyes and prolonged contact with the skin should be avoided. Wash thoroughly after handling material. It is recommended that MAKON products be stored in sealed containers and kept in a cool, dry place. If material is frozen it should be heated gently and stirred to ensure it is homogeneous before use.

Bulk Storage Information

MAKON surfactants can be stored in vessels of 316 stainless steel, but carbon steel is adequate. Material should be stored between 100 - 110 °F. An internal hairpin coil of carbon steel with low pressure steam (under 50 psig) should be used if heating is required. Mild agitation is required if the tank is heated. Material is heat sensitive and agitation prevents localized heating. Heating may not be required for inside storage if the tank is turned over frequently. Stainless steel 316 is preferred for pumps, pipes and transfer lines; however, carbon steel is adequate.

Workplace Exposure

Occupational exposure can occur primarily through skin contact or via inhalation of vapors and mists. Engineering controls, personal protective equipment, and other workplace practices should be used to control these exposures.