company tower banner
Ensinger GmbH Company Logo

TECACOMP LCP LDS black 1049426

1 of 151 products in this brand

Polymer Name: Liquid Crystal Polymer (LCP)

Processing Methods: Injection Molding

Technical Data Sheet

Similar Products

  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Technologies

Features & Benefits

Main Features
Developed for the LPKF-LDS® process Low thermal expansion

Applications & Uses

Plastics & Elastomers Processing Methods

Properties

Color
Flame Rating
Physical Form
Mechanical Properties
ValueUnitsTest Method / Conditions
Charpy Impact Strength15kJ/m2DIN EN ISO 179-1eU
Elongation at Break1.6%DIN EN ISO 527-1
Modulus of Elasticity (Tensile test)9700MPaDIN EN ISO 527-1
Tensile Strength85MPaDIN EN ISO 527-1
Thermal Properties
ValueUnitsTest Method / Conditions
Glass Transition Temperature221°CISO-R 75 Method A
Melting Temperature310°C-
Service Temperature (long term)200°C-
Service Temperature (short term)260°C-
Specific Heat1.11J/(g*K)DIN EN 821
Thermal Conductivity (in-plane)2.14W/(K*m)DIN EN 821
Thermal Conductivity (through-plane)0.46W/(K*m)DIN EN 821
Thermal Diffusivity (in-plane)1.1mm2/sDIN EN 821
Thermal Diffusivity (through-plane)0.24mm2/sDIN EN 821
Thermal Expansion (CLTE) Longitudinal (at 100 - 150°C)1110^-6 K^-1DIN EN ISO 11359-1;2
Thermal Expansion (CLTE) Longitudinal (at 150 - 200°C)1410^-6 K^-1DIN EN ISO 11359-1;2
Thermal Expansion (CLTE) Longitudinal (at 200 - 250°C)1310^-6 K^-1DIN EN ISO 11359-1;2
Thermal Expansion (CLTE) Longitudinal (at 50 - 100°C)810^-6 K^-1DIN EN ISO 11359-1;2
Thermal Expansion (CLTE) Transverse (at 100 - 150°C)4410^-6 K^-1DIN EN ISO 11359-1;2
Thermal Expansion (CLTE) Transverse (at 150 - 200°C)5310^-6 K^-1DIN EN ISO 11359-1;2
Thermal Expansion (CLTE) Transverse (at 200 - 250°C)6410^-6 K^-1DIN EN ISO 11359-1;2
Thermal Expansion (CLTE) Transverse (at 50 - 100°C)3410^-6 K^-1DIN EN ISO 11359-1;2
Typical Properties
ValueUnitsTest Method / Conditions
Density1.74g/cm3-
Electrical Properties
ValueUnitsTest Method / Conditions
Dielectric Constant (Test frequency: 1 GHz)53 .79 x 10^-3--
Resistance to Tracking (CTI)150VDIN EN 60112
Surface Resistivity1.3 x 10^15ΩDIN EN 61340-2-3
Volume Resistivity2.8 x 10^15Ω*mDIN EN 61340-2-3
Other Properties
ValueUnitsTest Method / Conditions
Bulk Density0.97g/cm3EN ISO 60
Flammability (at 3.2 mm, UL94)V0-DIN IEC 60695-11-10
Laser Marking Parameter (Forward movement)1.6 - 3.2m/s-
Laser Marking Parameter (Frequency)100 - 200kHz-
Laser Marking Parameter (Power)2 - 5W-
Molding Shrinkage (longitudinal)0.03%DIN EN ISO 294-4
Molding Shrinkage (transverse)0.56%DIN EN ISO 294-4
Water Absorption (23°C / 50% relative humidity up to saturation)max. 0.1%DIN EN ISO 62

Regulatory & Compliance

Certifications & Compliance