Karnak Roofing 502 RC-W Elasto-Kote Base Coat

KARNAK 502 RC-W Elasto-Kote Base Coat is intended for use on metal roofs (includes a rust inhibitor), spray polyurethane foam roofs, EPDM, TPO, and most PVC roof membranes. Also good over previously coated surfaces as well as for coating concrete, concrete block, brick, cinder block, stucco and wood. Maybe applied over KARNAK 405 Bond-N-Shield Base Coat over smooth BUR and smooth or granule modified bitumen membrane roofs. PVC and TPO roofs should be at least 4 years old before coating.

Product Type: 1K (1 component) Coating, Base Coat, Elastomeric Coating

Application Area: Roofing Membranes

Compatible Substrates & Surfaces: Brick, Concrete, Elastomers & Rubbers, Ethylene Propylene Diene Monomer (EPDM), Metal, Plastics, Polyurethane, Polyvinyl Chloride (PVC), Thermoplastic Polyolefin (TPO), Wood

Features: Excellent Elasticity, Self-Priming

Application Method: Brush, Roller, Spray

  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Features & Benefits

Labeling Claims
Ready-to-Use Product Features

Applications & Uses

Application Area
Application Method
Uses

502 RC-W Elasto-Kote Base Coat is intended for use on metal roofs (includes a rust inhibitor), spray polyurethane foam roofs, EPDM, TPO, and most PVC roof membranes. Also good over previously coated surfaces as well as for coating concrete, concrete block, brick, cinder block, stucco and wood. May be applied over 405 Bond-N-Shield Base Coat over smooth BUR and smooth or granule modified bitumen membrane roofs. PVC and TPO roofs should be at least 4 years old before coating.

Surface Preparations

All roof surfaces to be coated should be clean and free of dirt, dust flaking and pitting rust, grease, oil, and loose paint. Recommended application temperature is 40°F to 120°F. New metal must be allowed to age 30 days and new masonry surfaces should be allowed to cure 30 days, before coating. EPDM roof surfaces should be cleaned with 507 SPC Primer/Wash. Other roof surfaces should be cleaned with 799 Wash-N-Prep Roof Cleaner and water. Patch and repair all seams, flashings with 502MS Karna-Flex and Resat-Mat or appropriate sealants and caulking materials. Contact KARNAK Technical Services at 800-526-4236 for questions regarding surface preparation.

Application

Mix lightly prior to application of the coating. 502 RC-W Elasto-Kote Base Coat may be applied by brush, airless spray equipment or roller. For applications in higher temperatures (above 90 °F) KARNAK recommends application in multiple thin coats to prevent trapped moisture problems. Commencement of work by the contractor implies his approval of the deck surface. ROLLER / BRUSH APPLICATION Apply with a 3/4" – 1-1/4” nap roller or soft roof brush. SPRAY APPLICATION Utilize an airless spray pump. Equipment manufacturer should be consulted for more complete information. Spray application should be done with a 30% over-spray pattern.

Coverage Rate

Apply 502 RC-W Elasto-Kote Base Coat at the rate of 1.5 gallons per 100 sq. ft. (24 wet mils). Allow base to dry 24 hours before applying 502 RC-W Elasto-Kote Finish Coat. Coverage rate will vary due to texture and porosity of the surface. Film thickness should be approximately 18-20 dry mils. 502 RC-W Elasto-Kote Base Coat will take approximately 4-6 hours to dry to the touch. EPDM roofs should first be coated at the rate of 0.5 gallons per 100 sq. ft. (8 wet mils) followed by two coats of 502 RC-W Elasto-Kote Finish Coat at 1.25-1.5 gallons per 100 sq. ft. per coat (20-24 wet mils).

Properties

Physical Properties
ValueUnitsTest Method / Conditions
Weight per Gallon9.82 lbs.--
Solids by Weight55%, Nominal--
Solids by Volume40%, Nominal--
ColorGray--
Hardness, Shore A65.0--
Elongation715%, Nominal ASTM D 2370--
Tensile Strength1,182 PSI, Nominal ASTM D2370--
Permeability0.01 Perm--
Water Absorption (7 days)0.004--
Cure Time12 to 24 hours@ 77°F and 50% Relative Humidity--
Application Temp.40°F to 120°F--

Regulatory & Compliance

Certifications & Compliance

Safety & Health

Caution

Do not use near open flame. Avoid breathing solvent fumes and prolonged contact with skin. Do not take internally. If swallowed, do not induce vomiting. Call a physician immediately. Keep out of reach of children. Coating must be dried before exposure to water. Store in a heated room and keep container covered when not in use. Do not thin. Dispose of in an environmentally safe manner. Cover air intakes during application and while drying. For exterior use only. Cold-process systems and coatings, either emulsion or solvent-based, should only be installed on decks with positive drainage. Per NRCA (National Roofing Contractors Association), “The criteria for judging proper slope for drainage is that there be no evidence of standing water on a deck 48 hours after it stops raining.”

Packaging & Availability

Packaging