Knowde Enhanced TDS
Identification & Functionality
- Product Type
- Technologies
Features & Benefits
- Ready-to-Use Product Features
- Key Advantages
- UV resistant
- Waterborne
- Excellent clarity
- Low maintenance finish
- Fast dry time
- Excellent abrasion and mar resistance
- Seals substrate from moisture penetration
Applications & Uses
- Applications
- Key Considerations
- Substrate temperature must be a minimum of 50ºF
- Substrate must be free of dirt, waxes, curing agents,and other foreign materials
- For indoor use only, do not use in exterior areasexposed to rain or ponding water
- Application
Surface Preparation
Surface Preparation is the most critical portion to any successful resinous flooring system application. All substrates must be properly prepared as outlined in Key Resin Technical Bulletin #1. Work must be performed by trained or experienced contractors or maintenance personnel.
Mixing Instructions
KEY #803 can be easily applied. Apply with low pressure pump at 200-600 ft2 per gallon. Can also be brushed, rolled, or spread using a lamb’s wool/microfiber applicator. Coverage will vary due to ambient temperature, surfacetemperature, surface porosity, and/or application methods. Do not apply if surface temperature is below 50ºF. Avoid pooling and application to exterior areas that are subject to rain or ponding water. A single coat will seal the substrate to minimize staining while producing a “patina” like finish. Subsequent coats will create a surface film with a higher sheen. Care should be taken to minimize the entrapment of air caused by overrolling. Two or more coats are recommended for sealing applications.
Clean Up
Clean skin with soap and water. Tools and equipment should be cleaned with xylene or lacquer thinner.
- Maintenance
After completing the application of KEY #803, the installer should provide the owner with maintenance instructions. KEY #803 is easily cleaned with neutral soaps or detergents.
Properties
- Color
- Typical Properties
- Note
*Good air movement and humidity control are necessary for proper drying of waterborne coatings.
Value | Units | Test Method / Conditions | |
Cure Time Dry to Touch (75°F) | 15 - 30 minutes | - | - |
Cure Time Recoat (75ºF)* | 1.0 | hour | - |
Cure Time Light Foot Traffic Service (75°F) | 24.0 | hours | - |
Cure Time Full Cure & Maximum Resistance (75°F) | 5 Days | - | - |
Mixing Ratio | Single Component | - | - |
Solids Content (by Volume) | 20.0 | % | - |
Volatile Organic Content (VOC) | 90.0 | g/l | EPA Method 24, Compliant to low VOC Rule 1113 in all 50 states |
Flash Point | None | - | Setaflash Test |
pH | 8.5 – 8.9 | - | - |
Weight (Mixed) | 8.5 | - | - |
Thinning | No thinning is required. Apply at packaged consistency. | - | - |
Packaging & Availability
- Availability
Key Resin materials are available throughout the United States, Canada, and a number of other countries.