Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Fillers Included
- Polymer Name
- Plastics & Elastomers Functions
- Technologies
Features & Benefits
- Materials Features
- Key Features
- Toughness
- High Flow
- Temperature And Chemical Resistance
Applications & Uses
- Applications
- Plastics & Elastomers Processing Methods
- Typical Applications
In the electronics industry for the production of connectors, wiring device, frequency divider and a variety of instrument components, such as shell
- in the aerospace industry for the production of high strength, high temperature resistant and insulation of the high performance requirements of thin-walled parts;in the chemical industry for the production of corrosion-resistant valves, insulation devices in military products, for the production of precision electrical connectors, high strength, high temperature resistant contactor shell, motor module, pump impeller, pump, chemical pump etc.
Properties
- Mechanical Properties
- Thermal Properties
- Typical Properties
- Electrical Properties
- Processing Parameters
Value | Units | Test Method / Conditions | |
Tensile Strength | 160 | mPa | ISO 527 |
Elongation at Break | 1.9 | % | ISO 527 |
Flexural Modulus | 11 | GPa | ISO 178 |
Flexural Strength | 250 | mPa | ISO178 |
Charpy Impact Strength (V-notched) | 11 | kJ/m² | IS0 179 |
Value | Units | Test Method / Conditions | |
Melting temperature (10°C/min) | 280 | °C | ISO 11357 |
Heat Deflection Tem p High Load (1.8MPa) | 260 | °C | ISO 75 |
Flammability | V-0 | class | UL-94 |
Value | Units | Test Method / Conditions | |
Density | 1570 | kg/m³ | ISO 1183 |
Mold shrinkage (Machine Direction) | 0.4 | % | GB/T 15585 |
Mold shrinkage (Transverse Direction) | 0.7 | % | GB/T 15585 |
Water Absorption (23°C-sat) | 0.02 | % | ISO 62 |
Value | Units | Test Method / Conditions | |
Dielectric Strength | 16 | KV/mm | IEC 60243 |
Dielectric Constant | 4 | - | IEC 60250 |
Dissipation Factor | 0.002 | - | IEC 60250 |
Volume Resistivity | 2.2×10^15 | Ω.cm | IEC 60093 |
CTI | 125 | V | IEC 60112 |
Value | Units | Test Method / Conditions | |
Drying at 3h | 150 | °C | - |
Injection Pressure | 30~100 | mPa | - |
Injection Molding Melt Temperature | 290~330 | °C | ISO 294 |
Injection Molding Melt Temperature | 120~160 | °C | ISO 294 |
Limit in-cylinder retention time at 300°C | min. 60 | - | - |
Limit in-cylinder retention time at 300°C | min. 38 | - | - |