Load Out™ is designed to enhance the performance and consistency of post emergent herbicides, to reduce or eliminate the tie-up of anionic (amine salts) herbicides with divalent and trivalent cat ions, such as Iron, Magnesium and Calcium. These ions are often associated with hard water and high pH water. Load Out™ is designed to enhance the performance and consistency of glyphosate (an anionic herbicide) based herbicides. Load Out™ is designed to enhance and improve the consistency of all anionic herbicide included: the phenoxy’s (2,4-D, MCPA, MCPP), Dicamba (Banvel®), tirclopyr (Garlon™), fluroxypry (Starane™) clopyralid (Stinger™), quiclorac (Facet®), picloram (Tordon®), diclofop (Hoelon®), fenoxaprop (Puma®) clodinafop (Discover®) sethoxydim (Poast®), glyphosate (Roundup®), glufosinate (Liberty®), bromoxynil (Butril® Bronate®), haloxyfop (Verdict®), quizalofop (Assure®), imazamethbenz (Assert®), imazapyr (Arsenal), imazaquin (Scepter®), imazethapyr (Pursuit®) and imazamox (Raptor®). Load Out™ will also enhance the contact effect of most post-emergent herbicides. Load Out™ should not be used with Sulfonyl urea or sulfonamide herbicides. Mix Load Out™ at the rate of 1-4 quarts of per 100 gallons of total spray for use with products such as Rodeo®, Roundup®, Touchdown®, Glyphos®, Glyphomax®, Banvel®, Garlon™, Starane™, Stinger™, Tordon®, Facet®, Hoelon®, Puma®, Discover®, Poast®, Liberty®, Butril Bronate®, Verdict® Cacodylic Acid, dalapon, Diquat, Diuron, Goal®, Hyvar X®, Krovar 1, MSMA. Do not lower the pH of these tank mixtures below 4.0 as precipitates may form. Where use rates of Load Out™ adjuvant are below 2 quarts per 100 gallons are used, the addition of 1 pint of a good nonionic surfactant per 100 gallons 0.25% v/v applications or 1 quart nonionic surfactant for 0.5% v/v application may be desirable.
- Features
- Replaces NON-AMS Water Conditioners
- Reduces pHH
- Replaces NIS (Non-lonic Surfactant)
- Replaces AMS
- Counteracts Hard Water
Applications & Uses
- Markets
- Applicable Crop
- Application Technique
- Directions For Use
USE THIS PRODUCT ONLY AS SPECIFIED ON LABEL. Load Out™ adjuvant should be added to the spray water with adequate agitation prior to the addition of the pesticide, plant growth regulator or desiccant. Fill the tank half full add Load Out™ finish filling then add the pesticide. This should give time for Load Out™ to react with the hard water cations. Load Out™ adjuvant is intended to tie up cations, condition the spray water and enhance the penetration of the cuticle for many anionic (negatively charged), acid or salt formulations of fungicides, herbicides, insecticides, defoliants, desiccants, miticides and plant growth regulators. Load Out™ adjuvant reduces the adverse effects that alkaline waters have on the spray solution and provides additional wetting of the sprayed foliage. Load Out™ contains a surfactant therefore can replace other surfactant only products. Where use rates of Load Out™ adjuvant are below 2 quarts per 100 gallons are used, the addition of 1 pint per 100 gallons of good quality nonionic surfactant may be desirable.The concentration of Load Out in the spray tank cannot exceed 25% of the total amount of formulated herbicide and/or 10% of the total amount of formulated insecticide(s) and/or fungicides.
- Which one do you want to haul out to the field?
Properties
- Physical Form
Technical Details & Test Data
- Technical Data
Load Out's Unique Hard Water Scavenger System is a lot More Effective than AMS. Over the years there have been many AMS replacement products (water conditioners). Load Out is not one of them. Load Out will Out Perform AMS and it out Performs Other Water Conditioner.
- Test Data
Load Out is designed to maximize the performance of glyphosate based herbicides
More Available Glyphosate- More Active Form
- Increased Uptake
Better Performance
- Principal Functioning Agents
Alkyl amine ethoxylate, sulfuric acid 34.00% Constituents Ineffective as Spray Adjuvants 66% TOTAL 100.00%
Safety & Health
- Safety
- HAZARD STATEMENT: HARMFUL IF SWALLOWED. MAY CAUSE AN ALLERGIC SKIN REACTION. CAUSES SERIOUS EYE DAMAGE. MAY CAUSE. RESPIRATORY IRRITATION. VERY TOXIC TO AQUATIC LIFE.
- PRECAUTIONARY STATEMENT Danger—corrosive to eyes and irritates skin. Do not get in eyes. May cause skin irritation and eye damage. Avoid contact with spray. Avoid breathing spray mist. SKIN: Wear suitable protective equipment to protect skin, such as: synthetic rubber or non-nylon plastic apron, gloves, pants, and boots. Wash with soap and water after contact with skin. Shower at the end of the working day. DO NOT WEAR contaminated clothing. Remove contaminated clothing and wash before reuse. EYES: Protective eyewear MUST be worn
- PERSONAL PROTECTIVE EQUIPMENT Wear protective gloves / protective clothing / eye protection / face protection
- ENVIRONMENTAL HAZARDS Do not contaminate water by cleaning of equipment or disposal of wastes, use this product only as specified on label. Not for aquatic use.
- PHYSICAL OR CHEMICAL HAZARDS Concentrated Load Out: Wash spillage off thoroughly. These same precautions should be observed in equipment stored after use. Do not allow Load Out to come into contact with undiluted chlorate desiccant as an explosion may result. Clothing: Load Out may be hard on cotton, nylon, and leather clothing. If Load Out contacts clothing of this type, flush thoroughly with water to minimize damage. Wear non-nylon plastic protective clothing. Weight 8.8 lbs /gallon.
FIRST AID
- IF SWALLOWED wash out mouth thoroughly with water. Get medical attention. Contact a Poison Control Center. Do not induce vomiting.
- IF IN EYES Immediately flush with plenty of water for at least 15 minutes. Get medical attention.
- IF ON SKIN Immediately flush with plenty of water while removing contaminated clothing. As soon as soap is available, wash thoroughly with soap and water. Wash clothing before reuse.
- IF INHALED Remove to fresh air if breathing is difficult. Give oxygen and call a physician. F
Storage & Handling
- Storage
STORAGE AND DISPOSAL DO NOT CONTAMINATE WATER, FOOD OF FEED BY STORAGE OR DISPOSAL.
Do not store at temperatures above 140°F. DISPOSAL: Triple rinse container and pour rinsate into spray tank. Do not reuse container. Recycling decontaminated containers is the best option of container disposal. The Agricultural Container Recycling Council (ACRC) operates the national recycling program. To contact your state and local ACRC recycler visit www.acrecycle.org. Dispose of contents/container in accordance with local/national regulations.