Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Polymer Name
- Technologies
- Product Families
Features & Benefits
- Materials Features
Applications & Uses
- Applications
- Plastics & Elastomers End Uses
- Antimicrobial TPU Film Applications
- Performance Textiles
- Athletic & Outdoor Apparel
- Advanced Wound Care Products
- Medical Mattresses & Mattress Covers
- Footwear
- Diapers
- Hospital Gowns
Properties
- Physical Form
Technical Details & Test Data
- Test Data
Plate Number Sample Name Content 1 DT-1001 Virgin Polyether Polyurethane
2 DT-1001-AM 1st-Tier Antimicrobe Level
3 Control Virgin Polyethylene
Test: JIS Z 2801*
Number of Living E-Coli BacteriaPlate Number Sample Name Start of Test After 24 Hours % Reduction 1 DT-1001 130,000 1,000,000 98.7 2 DT-1001-AM 130,000 <100 >99.99 3 Control 130,000 77,000,000 - Test: JIS Z 2801*
Number of Living Staphylococcus BacteriaPlate Number Sample Name Start of Test After 24 Hours % Reduction 1 DT-1001 110,000 73,000 98.79 2 DT-1001-AM 110,000 <100 >99.999 3 Control 110,000 36,000,000 - - The test results shown here have been excerpted from actual laboratory test reports. The display of this test data is not intended to imply that similar results will be achieved in all applications and environments.
- * Results may differ depending on the application, use, and environment.
- * Actual field testing and determination of effectiveness and suitability for use is the responsibility of the manufacturer of the final product or device.
- * No warranty of effectiveness or suitability for use is expressed or implied by American Polyfilm, Inc.
Packaging & Availability
- Availability
This urethane film is available from 1 mil and in widths up to 78 inches.