Tracit™ 300 is a heat transfer compound (cement) hardens when cured. This product is recommended for use on steam or electric tracing (tubing) attached to process pipes. Also for valves, elbows, or anywhere there is a desire to maintain temperatures above or below ambient. A single heat tracer utilizing TRACIT-300 is equal to three or more bare tracers. May also be used on plate-type coil applications exceeding the temperature limits of non-hardening compounds.

Application Area: Pipes

Features: Good Bonding Strength, High Temperature Strength, Water Soluble

Application Method: Trowel

  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Features & Benefits

Applications & Uses

Application Area
Application Method
Installation
  • Remove lid and stir compound. If Tracit-300 has frozen, thaw before use.
  • Gloves and safety glasses are recommended during installation, as this product is slightly alkaline. Remove excess surface dirt, rust, etc. from contact surface before application for proper bonding.
  • For tracing applications, apply a thin layer (1/4 inch thick) with a mortar trowel to completely cover tracer tube. For non-tracing applications,
  • consult system manufacturer for further instructions.
  • Curing: Heat for 12-24 hours at 180°F to 212°F (82°C-100°C), or air-dry above 32°F until Tracit-300 has fully hardened.
  • Protect TRACIT-300 from water penetration. TRACIT-300 should never be exposed to acid.
  • Tracit-300 may be removed using water.
  • Chemax CC1 galvanized metal channels are recommended for faster
  • installation and weather protection. Sold in 4-ft. pieces.
Coverage Rates

Based on 1/8 inch application thickness. Apply by hand trowel. Flat surface coverage rate: 12 sq. ft. per gallon.

Tracer Size Process Line Size

Linear Feet/Gallon

3/8" O.D. 1 1/2" to flat 32
1/2" O.D. 1 1/2" to flat 28
3/4" O.D. 2" and larger 14
1" O.D. 3" to flat 9

 

Installation Instructions
  • Tracit-300 is slightly alkaline. Wear protective gloves and glasses when handling. Chemax CC Channels are recommended for use on straight tracing for faster installation, weather protection, and less wasted material. 
  • It is optimal to remove loose paint, rust, scale, grease, etc. with wire brush before applying Tracit-300. Using a brick (mortar) trowel, apply a thin layer (1/4") onto pipe line tracer, fully encasing it in the Tracit-300. For non-tracing applications, consult system manufacturer for further instructions.
  • Cure Tracit-300 by heating for 12-24 hours at 180°F to 212°F (82°C-100°C), or air-drying above 32°F until Tracit-300 has fully hardened. If application thickness exceeds an inch, apply compound in one-inch layers to reduce sagging. Allow Tracit-300 to cure between layer applications. No curing required when installing with Chemax CC Channels or with plate-type coil applications. 
  • Protect TRACIT-300 from moisture during installation. Do not expose to acid. May be removed using water.
  • Store at room temperature. Keep lid sealed tightly when not in use. If Tracit-300 has frozen, thaw before use.  A small amount of water (one ounce per gallon) may be mixed into the Tracit-300 if it has become too thick for application.

Properties

Soluble in
Water
Typical Properties
ValueUnitsTest Method / Conditions
Minimum Application Temperature32.0°F-
Maximum Usage Temperature750.0°F-
Minimum Usage Temperature-300.0°F-
Heat Transfer Coefficient (Heat source-pipe wall)20-40 Btu/hr•°F•ft2 (114-227 w/m2•°C)-
Bonding Strength200.0lbs. sq. in-

Packaging & Availability

Packaging Type
Stock Container Sizes

5-gallon can, 1-gallon can, quart can, pint can, 10 or 32 oz. caulk cartridge, 55-gallon drums.

Net Weight

14 lbs. (6.4 kg.) per gallon

Storage & Handling

Shelf Life

1.5 years in unopened can. Keep lid sealed tightly when not in use. Store at room temperature.