Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Polymer Name
- Technologies
- Product Families
Features & Benefits
- Materials Features
- Features
- High chemical resistance
- Operating temperature from -50 up to +80 °C
- Easy to weld
- Physiologically harmless
- Low-strain
Applications & Uses
- Markets
- Applications
- Plastics & Elastomers End Uses
- Plastics & Elastomers Processing Methods
- Applications
- Chemical engineering and tank building
- Drinking and waste water technology
Properties
- Physical Form
- Mechanical Properties
- Thermal Properties
- Typical Properties
- Electrical Properties
Value | Units | Test Method / Conditions | |
Mass Density | 0.95 | g/cm³ | ISO 1183 |
Melt Flow Index MFR (230°C / 2.16kg) | 11.0 | g/10min | ISO 1183 |
Melt Flow Index MFR (190°C / 21.6kg) | 11.0 | g/10min | ISO 1183 |
Yield Stress (50mm/min) | 23.0 | MPa | DIN EN ISO 527 |
Elongation at Yield (50mm/min) | 9.0 | % | DIN EN ISO 527 |
Modulus of Elasticity in Tension (1mm/min) | 800.0 | MPa | DIN EN ISO 527 |
Notched Impact Strength (+23°C) | 20.0 | KJ/m² | ISO 179 |
Hardness (15sec) | 64.0 | Shore D | ISO 868 |
Ball Indentation Hardness | 41.0 | MPa | ISO 2039-1 |
Value | Units | Test Method / Conditions | |
Coefficient of Linear Expansion | 1.5 - 2 | 10^-4 x K^-1 | DIN 53752 |
Value | Units | Test Method / Conditions | |
Flammability (Without Testing) | B2 | — | DIN 4102 |
Operating Temperature Range | -50 to 80 | °C | — |
Value | Units | Test Method / Conditions | |
Specific Volume Resistivity (1min, 1000V) | min. 10E+15 | Ω*cm | IEC 60093 |
Surface Resistivity | min. 10E+15 | Ω | IEC 60093 |
Dielectric Strength | 48.0 | kV/mm | IEC 60243-1 |
Dielectric Constant (50kHz) | 2.35 | — | IEC 60250 |
Dielectric Loss Factor (1kHz) | 2.35 | — | IEC 60250 |
Dielectric Loss Factor (10E+6 Hz) | 3.5 X 10E-4 | tan δ | IEC 60250 |
Packaging & Availability
- Standard Dimensions
- 2000 x 1000 x 8 - 100 mm