- Miracote MiraGard Enriching Sealer allows moisture vapor transmission and possesses very good stain resistance. It is compliant with Industrial Maintenance Coating Guidelines and the South Coast Air Quality Management District (SCAQMD) Rule 1113.
- Miracote MiraGard Enriching Sealer maintains a clean appearance and is highly resistant to deterioration when exposed to routine mild cleaning materials such as citrus, light TSP and surfactant cleaners.
- Resists a wide range of in-service chemicals and is very stain- resistant to a wide variety of industrial chemicals. Staining resistance and cleaning capability improves after 30 days.
- ADA Compliant: for in-situ, validate ADA Compliance with a Variable Incident Tribometer Machine.
- LEED (Leadership in Energy and Environmental Design) credit points may be available under several different classifications.
- Does not contain chemicals targeted by Green Seal Standard GS-11 and LEED-CS as unacceptable.
Applications & Uses
- Markets
- Usage
- Designed for use as an easy-to-apply sealer for polished concrete.
- It is also an excellent enriching sealer for natural stone, brick, saltillo tile, and other concrete installations.
- MiraGard Enriching Sealer can be used in both interior and exterior service.
- It possesses excellent resistance to ultraviolet light including freedom from color change or degradation.
- For Best Results
Install a minimum 4‟ by 4‟ test area site mock up for approval of acceptable color, texture, finish, adhesion, and any other critical requirement acceptable to the owner prior to proceeding with the installation. Protect materials from excessive heat and cold and regularly check wet film thickness with mil gage and monitor consumption to ensure correct application thicknesses and rate are obtained.
- Installation Steps
- Surface Preparation – dry, clean and free of contaminants.
- Finish – Nano-structure penetrating film, minimal to no surface profile and build.
- Read entire label and MSDS before using. Apply 48 hours or longer, after polished concrete, brick, grout, or stone tile has been placed.
- Apply using a sponge, brush, paint pad, cotton towel, or sprayer.
- After 5-10 minutes, remove puddles or excessive sealer, using an absorbent paper towel or cotton cloth to avoid irregular penetration. After 60 minutes, re-apply a 2nd coat, following steps described above. Ready for use: 2-4 hours after last coat, if kept dry. Allow 12-24 hours before regular use. For full anti-stain properties to develop, allow up to 30 days. Clean applicator tools with isopropanol, followed by lukewarm water and soap (apply within a moderate temperature range, 40°F and above, best if surface temperature is less than 90°F.
Properties
- Typical Physical Properties
Value | Units | Test Method / Conditions | |
Stain Resistance (Hydrochloric Acid (10%)) | Excellent | — | 4 hour spot test |
Active Material | 67.0 | — | — |
VOC | max. 0.01 | g/L | — |
Coefficient of Friction-Rubber Shoe Surface (Level) | 0.8 | — | ASTM D2047 |
Coefficient of Friction-Rubber Shoe Surface (Incline) | 0.8 | — | ASTM D2047 |
Stain Resistance (Water) | Excellent | — | 4 hour spot test |
Stain Resistance (Motor Oil ) | Excellent | — | 4 hour spot test |
Stain Resistance (Transmission Oil (SAE30)) | Excellent | — | 4 hour spot test |
Stain Resistance (Bleach) | Excellent | — | 4 hour spot test |
Stain Resistance (Caustic Soda (50% NaOH)) | Excellent | — | 4 hour spot test |
Stain Resistance (Phosphoric Acid (10%)) | Excellent | — | 4 hour spot test |
Stain Resistance (Acetic Acid (10%)) | Excellent | — | 4 hour spot test |
Regulatory & Compliance
- Certifications & Compliance
Technical Details & Test Data
- Coverage Rates
800-1200 sq. ft. per coat/gallon. (Actual coverage rate varies depending on porosity of the substrate).
- Mix Ratio
Single component. Do not dilute with anything. Use as supplied.
- Limitations
- Substrate must be above 40o F (4.4o C) dry and free of excessive water vapor transmission with a relative humidity below 85% at time of installation. Miracote MiraGard Enriching Sealer is not a filmforming sealer. Harsh cleaning methods, combined with high alkaline, acidic, or solvent-based cleaners will affect product longevity. Use of strong cleaners such as a high pH strippers that contain a high level of sodium hydroxide or potassium hydroxide may require periodic reapplication of MiraGard Enriching Sealer depending on the frequency of cleaning operation, but usually within every three to five years.
- Do not apply over moving cracks, joints, or unsupported gaps. If sub-surface cracks after the coating is applied, the cracks can reflect through. Do not apply over working joints, expansion joints, or construction joints.
- The proper application of this product is the sole responsibility of the end user. Job site visits by Miracote representatives are a support service only and are not participatory in the quality or performance of the contractor. Supervision and quality control of work and contract are the sole responsibility of the contractor and user. Measure surface and ambient temperatures to assure application is within the acceptable range.
Packaging & Availability
- Packaging Type
- Packaging
- 1-gallon can
- 5-gallon pail
Storage & Handling
- Shelf Life & Storage
Shelf life will be one year from the date of manufacture as long as containers remain unopened and when material is store in a protected environment that is free from moisture, excessive heat and freezing temperatures, and direct sunlight.