company tower banner
Adhesives Research Company Logo
ARcare® 93363 is a medical grade, skin-friendly, pressure-sensitive adhesive coated on a stretchable polyurethane nonwoven fabric. The adhesive side of the tape is protected by a clear polyester liner.

Product Type: Tape

Application Area: Medical Devices

Features: Biocompatible, Design Flexibility, High Moisture Vapor Transmission, Water Resistant

Technical Data Sheet
  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Backing Material Type
Product Type

Features & Benefits

Labeling Claims
Key Attributes
  • Excellent adhesion on skin for long-term wear
  • High moisture vapor transmission
  • Water resistance
  • Biocompatible per ISO 10993
  • Facilitates design options
  • Residue-free removal

Applications & Uses

Application Area
For Best Results
  1. The surfaces you wish to bond should be clean and free of oil, moisture and dust. If the surface temperature is below 40°F, it may be difficult to achieve a proper bond.
  2. Do not use a pressure-sensitive adhesive product where it will be exposed to temperatures lower or higher than those designated for each product. Heat can destroy the effectiveness of the bond and extreme cold can cause the adhesive to harden and not adhere properly.
  3. When the tape is applied, use firm hand or lamination pressure to achieve contact between the adhesive and the surface to which it is applied. Hand rollers or nip rollers may be needed for certain products or applications.

Consult your AR sales representative if you need additional information.

Applications

The typical use for this product is bonding on skin for long-term wear applications including adhesion of wearable load-bearing devices on skin.ARcare® 93363 - Applications

Properties

Color
Typical Properties
ValueUnitsTest Method / Conditions
Moisture Vapor Transmission Rate550.0g/m²/dayART4047
Moisture Vapor Transmission Rate550g/m²/dayPayne Cup Method
Peel Adhesion on Stainless Steel9.75N/25mm90 degrees, 12 ipm, 15 minute dwell
Recommended Storage of Unconverted Product (50% ± 20% RH )21 ± 11°C
Release of Polyester Liner~160g/2”90 degrees, 12 ipm
Static Shear~35min500 g, ½” x ½”
Peel Adhesion on Stainless Steel (90 degrees, 12 ipm, 15 minute)9.7N/25mm
Release of Polyester Liner (dwell)approx. 160g/2”
Static Shear (500 g, ½” x ½”)approx. 35minute

Regulatory & Compliance

Certifications & Compliance

Technical Details & Test Data

Product Construction
  Typical Values Description
Carrier thickness 7.0 mil 178 μm White PU non-woven carrier
Adhesive thickness 2.6 mil 66 μm MA-91 medical grade adhesive
Liner thickness 2.0 mil 50 μm Clear polyester liner
Total thickness 9.6 mil 244 μm (Excluding liner)

 

Note
All stated values are nominal and should only be used as a guide for selection. They are not specifications. The information contained on this data sheet is based upon test results of limited quantities of this material and may be modified by Adhesives Research following additional production experience and evaluation. This data should not be used in preparing specifications. Products identified as developmental may be subject to modification by Adhesives Research, Inc.

Safety & Health

Safety Data
MA-91 is a medical grade adhesive. The adhesive passed cytotoxicity, primary skin irritation, and skin sensitization tests conducted by an independent laboratory. Additional safety information is available upon request.

Storage & Handling

Shelf Life
1 Year
Shelf life of Unconverted product
Not to exceed one year from date of manufacture
Storage of Pressure-Sensitive Adhesive Tapes
Pressure-sensitive adhesive tapes function as a mechanical product however, the adhesive itself is a chemical composition that can be sensitive to environmental conditions. A purchaser of pressure-sensitive adhesive products should be aware of the shelf life of each product and not purchase more than it can use before the expiration date. Shipping and storage conditions affect shelf life. The optimum storage temperature is 70 °F (21 °C). Cool, dry storage is recommended.
Recommended Storage of Unconverted Product
21 ± 11 °C (50% ± 20% RH)