ATP® 361 is water-based, ceramic coating formulated to protect titanium alloys against oxide scale, alpha case development, and hydrogen absorption.

Product Type: Ceramic Coating, Waterborne Coating

Features: Chipping Resistance, Crack Resistant, Good Green Strength, High Temperature Performance, Peel Resistance, Water-based

Compatible Substrates & Surfaces: Glass, Metal, Titanium

Application Method: Brush, Dip Coating, Spray

  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Carrier

Features & Benefits

Performance Characteristics
  • Effective temperature range 1800-2200⁰F (982-1204⁰C)
  • Controls hydrogen penetration
  • Controls alpha case development
  • Provides heat distribution & metal movement
  • Demonstrates exceptional green strength upon proper drying to withstand cracking, chipping, peeling, etc.
  • Excellent paintability; formulated for brushing application (can be adjusted for dipping or spraying by diluting with water, do not thin coating too much)

Applications & Uses

Markets
Application Method
Compatible Substrates & Surfaces
Recommendations for Use
  • Thoroughly suspend and mix before use
  • Metal surfaces must be free of dirt, oil, grease, metal oxides, and other materials
  • Coating thickness depends on the time and temperature of exposure (generally, the higher the temperature and longer exposure, the thicker the coating should be applied)
  • A wet film thickness of 7 ± 3 mL should be optimal
  • Ensure bottom coat is thoroughly dried when applying multiple coats
  • Water-based coatings need ample time to completely dry before entering furnace (can be applied over preheated substrate to accelerate drying time)

Properties

Soluble in
Water
Typical Properties
ValueUnitsTest Method / Conditions
pH7.0 - 8.0--
Solids Content52.5 - 53.5%-
Viscosity (at 25°C)2,400 - 6,400cPs-
Weight per Gallon11.25 - 12.25 lbs-
Specific Gravity1.36 - 1.46--

Regulatory & Compliance

Certifications & Compliance
Regulatory Information

No chemical should be used as or in a food, drug, medical device, or cosmetic, or in a product or process in which it may contact a food, drug, medical device, or cosmetic until the laser has determined the suitability and legality of the use. Since government regulations and use conditions are subject to change, it is the user’s responsibility to determine that this information is appropriate and suitable under current, applicable laws and regulations.

Storage & Handling

Shelf Life
1 Year (approximate value)
Storage Conditions

ATP-361 should be stored indoors in the original unopened and undamaged container, in a dry place at a temperature not exceeding 85⁰F (30⁰C). Exposure to direct sunlight should be avoided.