Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Polymer Name
- Technologies
- Product Families
Features & Benefits
- Materials Features
- PRODUCT BENEFITS
- Chemical resistance
- UL94 V-0 flammability rating down to 0.59”
- Wear resistance
- Service temperature: -50°F to +500°F
- Hydrolysis resistance
- Radiation resistance
- FDA compliant
Applications & Uses
- Applications
- Plastics & Elastomers End Uses
- TYPICAL APPLICATIONS
- Thrust washers
- Pump gears
- Compressor valve plates
- Electrical connectors
- Valve seats and seals
- Bearings and bushings
Properties
- Flame Rating
- Physical Form
- Mechanical Properties
- Thermal Properties
- Electrical Properties
Value | Units | Test Method / Conditions | |
Density (Crystalline) | 1.3 | g/cm³ | ISO 1183 |
Hardness (23°C) | 84.5 | Shore D | ISO 868 |
Water Absorption (Immersion, Saturation, 23°C) | 0.45 | % | ISO 62-1 |
Tensile Strength (23°C) | Yield 98 | MPa | ISO 527 |
Elongation (23°C, Break) | 45 | % | ISO 527 |
Compressive Strength (23°C) | 125 | MPa | ISO 604 |
IZOD Impact Strength (23°C, Notched) | 8 | kJm-2 | ISO 180/A |
Flexural Modulus (23°C) | 3.8 | Gpa | ISO 178 |
Flexural Strength (3.5% Strain, 23°C) | 125 | Mpa | ISO 178 |
Flexural Strength (23°C) | Yield 165 | Mpa | ISO 178 |
Value | Units | Test Method / Conditions | |
Melting Point | 343 | °C | ISO 11357 |
Heat Deflection Temperature (Moulded, 1.8 Mpa) | 152 | °C | ISO 75-f |
Coefficient of Thermal Expansion (Avg. above Tg) | 55 | ppm K-1 | ISO 11359 |
Coefficient of Thermal Expansion (Avg. below Tg (143°C)) | 140 | ppm K-1 | ISO 11359 |
Thermal Conductivity (Avg., 23°C) | 0.29 | Wm-1 L-1 | ISO 22007-4 |
Continuous Use Temperature | 250 | °C | — |
Value | Units | Test Method / Conditions | |
Volume Resistivity (23°C) | 10^16 | ohm-cm | IEC 60093 |
Dielectric Strength (50 μm thickness) | 200 | Kv mm-1 | IEC 60243-1 |
Dielectric Constant (23°C, 1kHz) | 3.1 | — | IEC 60250 |
Loss Tangent (Dissipation Factor, 23°C, 1MHz) | 0.004 | — | IEC 60250 |
Regulatory & Compliance
- Certifications & Compliance
- Quality Standards
- COMPLIANCES
FDA compliant per 21CFR 177.2415
Technical Details & Test Data
- MATERIAL CLASS
- Mil-P 46183 Amendment 2, Dated July 1, 1999
- Type I - nonreinforced plastic
- Type III Class 2 - 30% carbon fiber reinforced