Knowde Enhanced TDS
Identification & Functionality
- Product Type
- Technologies
- Product Families
Features & Benefits
- Ready-to-Use Product Features
Applications & Uses
- Applications
- Application Method
- Typical Use
Klieg lights, space heaters and other applications that require heat resistant coatings.
- Coating Method
The ACA 10-100 may best be applied by rotogravure at a thickness of 0.1 to 0.2 mils. Curing is normally performed at about 400°F and 300 FPM in a 25 ft. oven. Operating conditions will vary with different ovens and coating weights and require some experimentation.
- Clean Up
Hose down the machine and direct the excess water to a drain. Warm soap and water may be used for the hard to clean areas of the coater. Dry, uncured coating can be removed with toluene. Toluene is an inflammable, volatile solvent and should be used in conformance with OSHA guidelines. The cured coating is very insoluble and difficult to clean from the equipment.
Properties
- Color
- Typical Properties
Value | Units | Test Method / Conditions | |
Crease Flex | No Cracks | — | — |
Dry Rub | Pass | — | — |
Heat Resistance (500°F) | Excellent | — | — |
Light Absorbent | 99.8 | % | — |
MEK Rub | 5 Times Pass | — | — |
Solids by Volume | 28.43 - 30.43 | % | — |
Solids by Weight | 33.55 | % | — |
VOC by Weight | 2.98 - 4.98 | % | — |
pH | 6.5 - 7.5 | — | — |
Thickness | 0.15–0.30 | mils | — |
Viscosity | 3,000 - 6,000 | cps | — |
Weight per Gallon | 9.097 | lbs. | — |