company tower banner
Anchor Paint Manufacturing Company Logo

Anchor Paint Manufacturing Ancothane Acrylic Urethane Series 4900

Ancothane Acrylic Urethane Series 4900 is a low VOC acrylic aliphatic urethane finish (two-component) providing very high gloss with excellent physical properties such as abrasionand chemical resistance, flexibility and weatherability.

Product Type: 2K (2 component) Coating, Enamel

Application Area: Tanks

Features: Chemical Resistant, Excellent Gloss Retention, Fast Drying, High Durability, UV Resistant

Chemical Family: Polyurethanes (PU)

  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Chemical Family

Features & Benefits

Applications & Uses

Application Area
Applications

Applications

  • Mixing/Mix Ratio: Mix 1 part, by volume, of #4906 into four parts urethane. Hand or mechanically agitate being careful not to
  • mix so fast that air is entrapped.
  • Pot Life: After # 4906 is mixed into the urethane at 80"F, the mixture must be applied within 2 hours. Adding #Cc0150

Accelerator also shortens pot life.

Temperature 40°F 80°F 100°F
Pot Life 9 Hours 2 Hours 1 Hour

 

  • Surface Temperature: Minimum 50°F
  • Recommended Thickness: 1.5-2.0 mils dry (Number of coats and thickness requirements will vary with substrate, application method
  • and service equipment)
  • Theoretical Coverage: 917 ftlgal at 1 mil dry, assuming no application losses. Coverage will vary depending on the color,

application technique, porosity and design of the substrate.

Application Equipment

Airless Spray (Pressure) 1200-2200 psi
Conventional Spray (Air Pressure) 60 - 80 psi
Conventional Spray ( Fluid Pressure) 10 - 20 psi psi

 

  • Brush: High Quality Pure China Bristle.
  • Roller: Short nap mohair roller with Phenolic Core.

This product is moisture sensitive until cured—avoid moisture contamination. For optimal performance apply when the relative humidity is less than 60%. Do not apply when the surface temperature is within 5°F of the dew point or when the relative humidity is greater than 80%. Do not apply when frost, dew, or rain is forecasted within the next 24 hours (72 hours in cooler temperatures). Apply first coat as a mist or tack coat prior to subsequent finish coats as specified by job requirements. Do not mix partial kits.

Where to Use

Ideal use in applications such as: bridges, storage tank exteriors, farm and shop equipment, and heavy machinery.

Preparation & Priming

  • New Work: For best performance on steel, the surface should be blasted to SSPC-SP6 or SSPC-SP10, including the removal of all mill scale. Prior to blasting, remove all flux and scab from welding and grind smooth all rough weld seams and sharp edges. Remove any grease, oil, or dirt with solvent (SSPC-SP1) or chemical cleaner before blasting. The surface should be coated within 24 hours after blasting. Apply over properly primed surface as detailed by applicable specifications.
  • Old Work: Substrate must be clean, dry and thoroughly degreased in accordance with SSPC-SP1 standards. All damaged areas should be repaired and existing paint should be in good condition. This coating may be applied over most old coatings in sound condition. Check the existing paint by applying on a trial patch and observe overnight for lifting, softening, or wrinkling. If this occurs, the existing paint must be removed or a compatible barrier primer must be applied first. Glossy surfaces should be sanded or brush blasted for best performance.
  • Primer Coats: Primer will be determined by service environment and job specifications.

Cleanup:Clean all tools and equipment with Anchor # TO003M MIBK Solvent. For disposal of empty containers and unused product, contact your household refuse collection service.

Properties

Typical Properties
ValueUnitsTest Method / Conditions
FinishHigh Gloss
Activator ReauiredAnchor # 4906 Activator
Solids by Volume (Varies by Color)57.16%
Recommended Thickness ( Mils dry)1.1 - 1.7
Dryig Time (40°F, To Touch)5.0hr
Dryig Time (40°F, Tack Free)48.0hr
Dryig Time (40°F, To Recoat)48.0hr
Dryig Time (40°F, To Hadle)5.0days
Dryig Time (40°F, Full Cure)min. 7days
Architectural and Industrial Maintenance CategoryIndustrial Maintenance Coatings
AIM Category VOC Limit450.0g/l
Actual VOC348.0g/l
Density1170.0g/l
Theoretical Coverage917.0ft² /gal
Storage Temperature20 - 110°F
Heat Resistance (350°F)Intermittent

Technical Details & Test Data

Performance Data

Substrate: Steel

Surface Preparation: SSPC-SP10

System Tested: 1 coat CC1738 Zinc Rich Epoxy II, 1 coat CC1514 Hi-Solids Epoxy Primer, 1 coat 4900 Ancothane Acrylic Urethane

Test Name Test Method Results
Accelerated Weathering ASTM D4587 2500 HRS

95% Retention of Gloss - 60°

Abrasion Resistance ASTM D 4060, CS17 wheel,1000 cycles 1 kg load 59.3 mg loss
Salt Fog Resistance ASTM B117, 5000 Hours

Blistering - None per ASTM D714,Rusting - 8 per ASTM D610

Hardness (Pencil) ASTM D 3363 H
Adhesion (Pulloff) ASTM D 4541 1000+ psi
Adhesion (Crosshatch) ASTM D 3359 5B

Dry Heat Resistance

 

250F Continuous 300 F Intermittent Discoloration is observed above 300F

Safety & Health

Safety Information
  • Flammable liquid and vapor. Vapor harmful. Contains: isobutyl ketone. Vapor harmful. May affect the brain or nervous system causing dizziness, headache or nausea. Causes nose, eye, skin and throat irritation. Harmful if swallowed. Notice: reports have associated repeated and prolonged occupational overexposure to solvents with permanent brain and nervous system damage. Intentional misuse by deliberately concentrating and inhaling the contents may be harmful or fatal.
  • Keep away from heat, sparks and flame. Vapors may cause flash fire. Close container after each use. Do not smoke. Extinguish all flames and pilot lights, and turn off stoves, heaters, electric motors and other sources or ignition during use and until all vapors are gone. Prevent build-up of vapors by opening all windows and doors to achieve cross-ventilation. Use only with adequate ventilation. Do not breathe vapors or spray mist. Ensure fresh air entry during application and drying. If you experience eye watering, headache or dizziness or if air monitoring demonstrates vapor/mist levels are above applicable limits, wear an appropriate, properly fitted respirator (niosh approved) during and after application. Follow respirator manufacturer’s directions for respirator use. Do not get in eyes, on skin or clothing. Wash thoroughly after handling. Keep out of reach of children.
  • If you scrape, sand or remove old paint, you may release lead dust. Lead is toxic. Exposure to lead dust can cause serious illness, such as brain damage, especially in children. Pregnant women should also avoid exposure. Wear a niosh-approved respirator to control lead exposure. Clean up carefully with a hepa vacuum and a wet mop. Before you start, find out how to protect yourself and your family by contacting the national lead information hotline at 1-800-424-lead or log on to www.Epa.Gov/lead. Warning! Sanding or scraping pressure treated lumber may be hazardous; wear appropriate protection.

Storage & Handling

Storage

Storage Temperature: Minimum 20°F & Maximum 110°F
Shelf Life: Under Normal Conditions (Unopened)- Two Years