company tower banner
Anchor Seal Company Logo

Anchor Seal SY6009T* Black

Anchor Seal SY6009T* Black is anchor-seal epoxy for potting compounds and encapsulants coils and transformers. It is used in low health hazard, thermal conducting switches.

Product Type: 2K (2 component) Sealant, Epoxy Sealant, Structural Sealant

Application Area: Power Transformers

Chemical Family: Epoxy & Epoxy Derivatives

Technical Data Sheet
  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Features & Benefits

Features
  • Fast curing
  • Thermally conductive
  • Low thermal expansion
  • Heat & chemical resistant
  • Abrasion resistant

Applications & Uses

Application Area
Applications
  • Adhesive & Coating
  • Insulators & bushings
  • Power supplies
  • Transformers
Mixing & Curing Instructions

Mix Ratio: 100 Parts A to 27 Parts B by wt.

Cure Schedule ¼” set time, 4-6 hours At 77°F.
Room cure, 16 hours At 77°F.
Oven cure 2-3 hours At 125-150°F
Directions for use

Stir contents prior to use. Because °F differences in density, pigments and fillers, when present, may separate from the liquid components during storage. To insure product homogeneity and maximum performance, check the containers for settling. If settling is evident, loosen any settled pigments from the bottom °F the container with a screwdriver or similar object. Hand-stir the contents with a metal mixing stick, or power mix at slow speed with a drill press and dispersion blade. This product might crystallize in its shipping container during storage. If it appears hard, or has a granular consistency, or if it is normally clear but appears cloudy, warm it thoroughly at 120°F to reconstitute. Remix the product and allow it to cool back to room temperature before using.

Measuring

Carefully weigh Part A and Part B components with an accurate scale. If measuring volumetrically, use precise metering pumps, graduated/pre-marked containers or pre-measured kits. Place the correct proportions °F Part A and Part B into a straight-sided container. Note: Altering the mix rati°From what is specified on the data sheet is not recommended. Cured properties could be adversely affected.

Mixing

: Mix thoroughly with a flat-ended stick or a slow speed drill press with a dispersion blade. Scrape the sides and bottom °Ccasionally to assure a thorough blend. Do not whip excessive air into the mixture. To guard against partially cured sections, never apply material scraped from the sides °F the original mixing container. For best results, transfer the mixture into a second container and stir it again before application. This will help insure consistent properties and maximum performance.

De-airing

: Low viscosity resins will de-air naturally on their own. Some applications require a totally air-free product. If a vacuum pump and chamber are used, evacuate the material for 5-15 minutes At 28-29 inches °F mercury. Allow sufficient space above the liquid for expansion, about four times the liquid volume. Resins slightly warmed are thinner and will de-air faster. Also, the use °F an air-out additive will lower the surface tension and hasten air release.

Caution: Warming a catalyzed mixture will shorten the pot life and decrease gel time.

Properties

Physical Properties
ValueUnitsTest Method / Conditions
Hardness (77°F)92.0Shore DDurometer
Specific Gravity (77°F)2.28g/cc
Tensile Strength (77°F)6900.0psi
Tensile Elongation (77°F)2.0%
Compressive Strength (77°F)17000.0psi
Moisture Absorption (7days At 25°C, 77°F)0.1%
Thermal Condition (Btu)10.0in/ft2(hr)(°F)
Thermal Expansion (Linear, 77°F)25 x 10-6m/cm/°C
Service Temperature (300°F, 77°F)150.0°C
Electrical Properties
ValueUnitsTest Method / Conditions
Dielectric Strength (77°F)475.0volts/milASTM D149
Dielectric Constant (1 KHz, 77°F)6.5ASTM D150
Dissipation Factor (1 KHz, 77°F)0.02
Volume Resistivity (77°F)5 x 10^15ohm-cmASTM D257
Uncured Properties
ValueUnitsTest Method / Conditions
Pot Life (50-100 gram mass, 77°F)30-40minutes
Viscosity (Part A, 77°F)170000.0cps
Viscosity (Part B, 77°F)6000.0cps
Viscosity (A:B mixed, 77°F)Limited flow paste
Specific Gravity (Part A, 77°F)2.35g/cc
Specific Gravity (Part B, 77°F)1.09g/cc

Safety & Health

Warning

For Industrial Use Only

All chemicals must be handled with care. Avoid breathing fumes, mists and dust, they could cause respiratory discomfort or damage. Work in a well-ventilated area. Avoid all contact with the skin. If contact °Ccurs, wash affected area thoroughly with soap and water. Repeated skin contact may cause dermatitis in susceptible individuals. Wear protective clothing and gloves. Severe irritation will result if this product is splashed into the eyes. Always wear eye protection. If eye contact °Ccurs, flood eyes with clear water for 15 minutes and immediately seek medical attention. Always maintain good industrial hygiene when using this product.

Storage & Handling

Shelf Life
2 year