Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Polymer Name
- Plastics & Elastomers Functions
- Technologies
Features & Benefits
- Labeling Claims
- Materials Features
- Processing Considerations
- BC 27150 is generally used for monolayer films and is designed to be used on existing equipment with a few adjustments.
- Films made with NuPlastiQ are more sensitive to processing conditions such as temperature profile, residence time, die gap, and blow-up ratio. See the NuPlastiQ/PBAT Film Processing Guide for additional information.
- A typical recommended temperature profile will be in the 130°C – 165°C range.
- Depending on equipment, process conditions, and residence time, as temperatures increase in this range the glycerin plasticizer may experience some volatilization. This may cause a slight odor and/or smoke and is expected under normal processing conditions. Always use proper ventilation. See the BioBlend® BC 27130 SDS for details.
- o Melt temperatures above 175°C may cause material degradation, lensing, and fish-eyes in the film.
- If extruder operation much be stopped temporarily, it is recommended to purge the material in the barrel before resuming film processing or material degradation will occur.
Applications & Uses
- Applications
- Compatible Polymers & Resins
- Plastics & Elastomers End Uses
- Plastics & Elastomers Processing Methods
- Applications
- BioBlend® BC 27150 is intended for agricultural mulch film.
- Used for products that require biodegradation or are intended for compost environments.
Properties
- Mechanical Properties
- Physical Properties
- Thermal Properties
- Typical Properties
- Film Properties
- Flexural Properties
Value | Units | Test Method / Conditions | |
Tensile Strength at Break | 14 | MPa | ASTM D638 |
Tensile Elongation at Break | 100 | % | ASTM D638 |
Tensile Secant Modulus (at 1%) | 210 | MPa | ASTM D638 |
Value | Units | Test Method / Conditions | |
Density (1) | 1.3 | g/cm3 | ASTM D792 |
Value | Units | Test Method / Conditions | |
Melting Temperature Range | 130 | °C | ASTM D3418 |
Glass Temperature Range | 81 - 100 | °C | ASTM D3418 |
Melt Flow Index (2) | 1.7 | g/10 min (190 °C/10 kg) | ASTM D1238 |
Value | Units | Test Method / Conditions | |
Moisture Content | approx. 0.5 | % | ASTM D6980 |
Value | Units | Test Method / Conditions | |
Dart Drop Test (3) | 180 | g | ASTM D1709 |
Elmendorf Tear MD (3) | 400 | g | ASTM D1922 |
Elmendorf Tear TD (3) | 550 | g | ASTM D1922 |
Elongation at Break MD (3) | 550 | % | ASTM D882 |
Elongation at Break TD (3) | 600 | % | ASTM D882 |
Tensile Strength MD (3) | 17 | psi | ASTM D882 |
Tensile Strength TD (3) | 17 | psi | ASTM D882 |
Value | Units | Test Method / Conditions | |
Flexural Modulus | 150 | MPa | ASTM D790 |
Regulatory & Compliance
- Certifications & Compliance
- Chemical Inventories
Packaging & Availability
- Country Availability
- Packaging Type
- Regional Availability
Storage & Handling
- Storage and Drying
- BioLogiQ BioBlends are dried after production and shipped in sealed moisture-proof bags that are ready to use as supplied. They should be stored indoors in the sealed container away from heat until used.
- If pellets are exposed to a humid environment, they will absorb moisture from the air. If needed, dry pellets by introducing warm dry air at no more than 60°C for 1-4 hours.
- The estimated moisture content of a BioLogiQ BioBlend can be measured with an infrared moisture analyzer at 105°C for 10 minutes. The result of the measurement will not perfectly equal the moisture content, due to possible partial evaporation of plasticizer. The result from this test should be <0.5% moisture prior to processing.