Complex imaging and corrosion inhibitor.
Features & Benefits
- HII Features
- Properties
deconex® 41 STS ALKA prevents the formation of deposits on the sink and in the machine, in nozzles and pipelines. The mildly alkaline product also prevents the formation of Kesselstein in the evaporator.
Applications & Uses
- Markets
- Applications
- Home Care Applications
- I&I Cleaning Applications
- Applications
Dosage
The dosing takes place via built-in dosing devices and amounts to:
Water hardness [°dH]
Water hardness [°fH]
Dosage
0 - 5 °dH 0 - 9 °f 1.0 mL/L 5 - 10 °dH 9 - 18 °f 2.0 mL/L 10 - 15 °dH 18 - 27 °f 3.0 mL/L 15 - 25 °dH 27 - 45 °f 4.0 mL/L min. 25 °dH min. 45 °f 5.0 mL/L - Instructions for Use
Flush the dosing lines well before changing the product.
Properties
- Appearance
- Clear, Colorless To Yellow
- Typical Properties
Value | Units | Test Method / Conditions | |
pH value (1% Solution in city water) | approx. 11.1 | - | - |
Density (Concentrate) | 1.12 | g/mL | - |
Regulatory & Compliance
- Regulatory Information
deconex® 41 STS ALKA meets the requirements for medical products in accordance with the Medical Products Regulation (EU) 2017/745.
Technical Details & Test Data
- Material Compatibility
Suitable for: Stainless steel, copper, cast iron, plastics, glass. Not suitable for: Aluminum. For non-named materials, you can conduct your own compatibility studies or order from Borer Chemie AG.
Packaging & Availability
- Packaging
The bindings, closures and labels are made of recyclable polyethylene.
Storage & Handling
- Storage and Transport
Store product at temperatures between 5 and 25 °C. This medicine product is sensitive to frost. Avoid transport whenever possible during the cold season. Should a transport be unavoidable during this time of year, the product must be sent in a truck / sea container tempered at least 5 °C. Alternatively, for short transport times below 10 hours and transport temperatures that do not fall below minus 5 °C, thermal protection hoods can also be used to protect the product.