Intumax DBK is a highly efficient phosphate based halogen free fire retardant intumescent agent. It has a slightly acidic pH, and is water insoluble. Intumax DBK is recommended for use in both indoor and outdoor application in two part urethanes. Applications where Intumax DBK has found utility vary greatly from urethane adhesives, non-skid coatings, and for secondary electrical applications in urethane potting and encapsulating systems. For further assistance and recommended starting formulations, please contact our technical staff.

Functions: Flame Retardant, Intumescent

Chemical Family: Phosphorous-based Compounds

End Uses: 2K (2 Component) Adhesive, 2K (2 Component) Sealant, 2K (2 component) Coating

Compatible Polymers & Resins: Polyurethanes (PU)

Labeling Claims: Halogen-free

Technical Data Sheet
  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

CASE Ingredients Functions
Technologies

Features & Benefits

Labeling Claims

Applications & Uses

Compatible Polymers & Resins

Properties

Physical Form
Typical Properties
ValueUnitsTest Method / Conditions
Purity99+%
Water Solubility (25°C)max. 1%
pH Value6.0 - 6.5
pH6.0 - 6.5
Water Solubility @ 25°Cmax. 1%

Technical Details & Test Data

Performance Data
  • ASTM E119 Fire Rating
  1. 90 minutes at 3/8” thick applied in one coat to unprepared steel (total time 1hr 54min)
  2. 2 hours at 0.5” thick applied in one coat to untreated/unprimed steel (total time 2 hr 20 min) 
  • ASTM E662 Smoke Generation Test
  Non-Flaming Flaming
Ds (1.5 min.) 0.5 1.7
Ds (4.0 min.) 1.1 51.7

 

  • BSS 7239 Toxic Gas Testing at 72.2o F, 52% relative humidity, and 30.07 in. Mercury
Gas  Ave PPM
CO 325.00
HCN 20.00
SO2 10.00
HCL 27.50
HF 0.00
NO 57.50
NO2 8.00

 

  • ASTM E162 Flame Spread Test - Class A
  • ASTM D256 (Method A) Izod Impact Testing
  1. Energy Consumption (foot-pounds) 0.47
  2. Impact Strength (foot-pounds-force per inch) 0.93
  • ASTM 2240 Hardness 70 Shore D
  • ASTM G53 1000 Hr UV Exposure
  1. After 1000 hours no visual cracking melting or spotting
  • ASTM B117 720 Hrs Salt Spray
  1. No loss of coating adhesion. No defects