Hyspin HLP 46 T can be universally applied wherever special thermal or mechanical loads require high-performance hydraulic oils.
The product has been approved under SEB 181222.
The product also meets the specifications of renowned manufacturers of hydraulic pumps and hydraulic motors, such as:- Dension HF-0, HF-2
- Vickers Industrial Equipment, I-286-S-Specification
- Cinicinnati M. – S. 68-69-70
Properties
- Typical Properties
Value | Units | Test Method / Conditions | |
Density (15°C / 59°F) | 875.0 | kg/m³ | ISO 12185 |
Kinematic Viscosity (40°C / 104°F) | 46.0 | mm²/s | ISO 3104 |
Kinematic Viscosity (100°C / 212°) | 6.7 | mm²/s | ISO 3104 |
Viscosity Index | 103.0 | - | ISO 2909 |
Pour Point | -30 (-22) | °C(°F) | ISO 3016 |
Flash Point - Open Cup Method | 224 (435) | °C(°F) | ISO 2592 |
Air Release (50°C / 122°F) | 6.0 | min | ISO 9120 |
Water Separation (54°C / 129°F, 40/37/3) | 10.0 | min | ISO 6614 |
Foam Sequence I (Tendency / Stability) | 0.0 | ml | ISO 6247 |
Foam Sequence II (Tendency / Stability) | 10.0 | ml | ISO 6247 |
Foam Sequence III (Tendency / Stability) | 0.0 | ml | ISO 6247 |
FZG Gear Scuffing Test (A/8.3/90) | 12.0 | - | ISO 14635-1 |