CIM® 1061 is a tough, abrasion, corrosion and chemical resistant, liquid applied coating specifically for use in water and wastewater applications including those which require ANSI/NSF 61 potable water certification. Typical applications for this two component elastomeric urethane coating include tank and reservoir liners, joint seals, tank repairs, and chemical containment.

Product Type: 2K (2 component) Coating, Elastomeric Coating

Features: Abrasion Resistant, Chemical Resistant, Good Toughness, Good UV Stability, Wear Resistant

Application Area: Tanks

Compatible Substrates & Surfaces: Concrete, Glass, Metal, Steel, Wood

Application Method: Roller, Trowel

Technical Data Sheet
  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Features & Benefits

Product Highlights

CIM 1061 is a liquid applied urethane coating that:

  • ANSI/NSF 61 approved for potable water contact up to 82°C.
  • Excellent wear and abrasion resistance.
  • Cures in hours to form a tough elastomeric coating
  • Ideal for coating concrete
Advantages

CIM 1061 is one of the toughest coatings available, specifically formulated to meet the demanding needs of the water/wastewater industries

  • Ideal for coating concrete.
  • ANSI/NSF 61 certified for potable water contact up to 180°F.
  • Tested to ANSI 118.10-199, "Standard Specification for Load Bearing, Bonded, Waterproof Membrane for Thin-Set Ceramic Tile and Dimension Stone Installation".
  • Forms a tough elastomeric coating able to bridge cracks and joints.
  • Meets the most demanding health and safety requirements for drinking water, fish hatcheries, and food processing plants.
  • Adheres to and bridges between common construction materials such as concrete, steel, glass, wood, and most coatings.
  • Environmentally sound, complying with the toughest VOC standards.
  • Can be repaired when damaged or when new tank penetrations are installed.
  • Excellent wear and abrasion service.
  • UV stable.
  • Bonds to most substrates    
  • Excellent adhesion provides a fully bonded waterproofing system
  • Approved to ANSI/NSF 61 Standard    
  • Suitable for contact with potable water for tanks as small as 5,000 gallons
  • Lowest permeability in industry    
  • Designed for constant immersion environments
  • High solids/low VOC    
  • Compliant to toughest VOC regulations
  • Suitable for applications in direct contact with UV
  • Excellent chemical resistant    
  • Resistant to strong acids and bases
  • Excellent Concrete Crack Bridging    
  • Bridge new cracks up to ¼ inch
  • Liquid, two-component urethane can be applied to complex tanks with multiple penetrations, and irregular shapes.

Applications & Uses

Application Area
Application Method
Compatible Substrates & Surfaces
Surface Preparation

General

  • Substrates must be clean and surface dry with no oils, grease or loose debris.
  • Perform adhesion tests to confirm adequacy of surface preparation.

Concrete

  • ICRI-CSP 4-6 surface profile exposing aggregate.
  • Concrete must exhibit minimum 3,000 psi compressive strength and be free of release agents and curing compounds.
  • The substrate must be clean, surface dry and free of contaminates.

Steel

  • Minimum 3 mil profile.
  • Immersion service – SSPC-SP10 / NACE No. 2 Near White Blast.
  • Non-Immersion service – SSPC-SP6 / NACE No. 3 Commercial Blast.

Other Metals

SSPC-SP1 solvent clean and abrasive blast to roughen and degloss the surface. Use CIM Bonding Agent for greater adhesion.

Glass

Thoroughly clean. ClIM Bonding Agent must be used for increased adhesion. For immersion service roughen the surface.

Previous Coatings and Linings

CIM 1061 may be applied over some existing coatings and linings and achieve acceptable performance. CIM Bonding Agent is recommended for greater adhesIon. inished system results vary due to a variety of project specitic tactors, including the service conditions to which the system is exposed. Iherefore, .I.M. Industries does not accept responsibility for determining the suitability of an existing coating or lining as a substrate for CIM products. Owner shall perform adhesion tests on any existing coating or lining to etermine suitability.

Earth : Use CIM Scrim

Color

CIM 1061 is initially shiny black, turning dull over 3 to 6 months when exposed to direct sunlight. For a colored or reflecting surface finish.

Temperature Conditions

Surface should be at least 50°F (10°C) and must be 5°F (3°C) above the dew point. Do not apply when the substrate or ambient temperature is rising or coating is in direct sunlight. CIM 1061 should be at least 60°F (15°C) when mixed and applied. ClM 1061 may be preheated to faciltate application at low temperatures, but working time will be reduced.

Mixing

DO NOT THIN. DO NOT HAND MIX. Begin mixing each pail (4.4 gal.) of CIM 1061 Premix using a pOwer mixer (e.g. 2 drill and an eight inch mud mixer). Do not draw air into the mix. While mixing, slowly add one jug (0.6 gal.) of CIM 1061 Activator to the pail and mix thoroughly for 3 full minutes. The proportions are premeasured; DO NOT ESTIMATE. Mixing Jigs and Timers from C.I.M. Industries help eliminate mixing errors and increase productivity on the job.

Application

Apply CIM 1061 directly to a clean and dry substrate. Vertical surfaces will require multiple coats. 

Equipment

Spray equipment requires large diameter hose and air supplied mastic gun or plural component spray equipment. Roller, squeegee, and trowel may also be used.

Priming

Porous substrates such as wood and concrete may be primed with CIM Epoxy Primer to minimize outgassing. The maximum recoat window for CIM Epoxy Primer is 48 hours. See the CIM Epoxy Primer lechnical Data sheet for additional intormation. Pertorm adhesion tests to confirm adequacy of adhesIon to primer.

Recoating

CIM 1061 may be recoated in 1 hour and must be recoated soon after the coating no longer comes off on polyethylene (typically within 4 hours of mixing). If the coating has cured longer than this time, the surface must be severely abraded using surface grinder or other mechanical means, and be free of dust and debris. Use CIM Bonding Agent for better adhesion. For immersion conditions, all coats shall be applied within four hours of each other, except at joint lines.

Recommended Minimum Thickness

Recommended minimum thickness of the coating is 60 wet mils. Additional thickness may be specified, but extended time is required to insure proper solvent release prior to placing the liner in service.

Curing Time

Before placing the coating into potable water service or similar applications, allow sufficient time for solvents to release from the coating. The required time for a 60 wet mil co0ating is
two weeks at 60°F (15°C) and varies depending upon coating thickness and substrate temperature. For many other applications, CIM 1061 may be placed into service in 24 hours.
.
Disinfection

CIM 1061 coating must be washed, rinsed, and disinfected in accordance with C.I.M. Industries Instruction Guide "Decontamination or Washing Procedures for Potable Water
Tank and Fish Pond Service" (IG-10).
Clean-up

Use mineral spirits for clean-up of uncured material. Spray equipment must be flushed regularly during application to prevent material from setting up in the hose and pump. Cured
material is very difficult to remove. Soaking in solvent will soften the material and may assist in its removal.

Properties

Typical Properties
ValueUnitsTest Method / Conditions
Solids by Volume (1416 dry mils x sq. ft./gal.)88.0%
VOC90 (0.75)g/l (lb./gal.)
Abrasion Resistance (Loss)1.2mgASTM D4060 CS-17 Wheel, 1000 rev
Adhesion to Concrete (Dry)350.0psiElcometer
Deflection Temperature (Minimum Use Temperature)max. -60ºFASTM D648
Density Premix8.0Ibs./gal.
Density Activator10.1Ibs./gal.
Density Mixed & Cured8.3Ibs./gal.
Elastomeric WaterproofingExceeds all criteriaASTM C836
Elastomeric WaterproofingExceeds all criteriaASTM C957
Extension to Break300.0%ASTM D412
Flooring and Shower LiningPassUPC/IBC ANSI 118.10
Green Roof Membrane/Root BarrierPassANSI/GRHC/SPRI VR-1 2011
Hardness65.0Shore AASTM D2240 at 77ºF
Liner Performance (Crack Bridging 10 cycles at -15ºF)min. 1/8
Liner Performance (Crack Bridging After Heat Aging)min. 1/4
Liner Weight (60 mil wet film thickness)31.0lbs./100 sq. ft.
Mix Ratio Weight6.2:1
Mix Ratio Volume7.8:1
Permeability to Water Vapor0.03permsASTM E96 Procedure B,100 mil sheet
Potable Water Service ANSI/NSF61 - 180°FUL File Number MH17445 WQA Certified
Recovery from 100% extension (After 5 minutes)98.0%
Recovery from 100% extension (After 24 hours)100.0%
Service Temperature-60 to 220ºF
Softening Point, Ring & Ballmin. 325ºFASTM D36
Tear Strength180.0lbs./in.ASTM D624 (Die C)
Tensile Strength1000.0psiASTM D412,100 mil sheet
Weathering5000hoursASTM D822
Flash Point Premix101.0ºF
Flash Point Activatormin. 400ºF

Regulatory & Compliance

Certifications & Compliance

Safety & Health

Precautions

Avoid contamination with water or moisture. Keep all pails and jugs tightly closed until ready for use. All equipment, air supplies, and application substrates must be ABSOLUTELY DRY. Do not apply in wet weather or when rain is imminent or when the CIM 1061 or the substrate may become wet within 4 hours after coating. Use caution when applying CIM 1061 in confined spaces.

Safety Information

This product contains petroleum asphalt, petroleum distillates, amine compounds and/or other chemical ingredients. Adequate health and safety precautions should be observed during the storage, handling, application and curing. 

Warning Flammable. Use only in well ventilated areas. Do not store or use near open flame, sparks or hot sufaces. Keep tightly closed. Avoid contact with moisture or water. Keep out of reach of children.

Packaging & Availability

Packaging

CIM 1061 is available in mixed units of O.8 gallons and 5 gallons. Each unit consists of a container of premix and a smaller container of activator. Quantities have been premeasured
to provide the proper mixing ratio, leaving sufficient room in the premix container to facilitate adequate mixing. Do not estimate proportions.

Storage & Handling

Shelf Life
1 year (Activator), 2 years (Premix)
Storage
  • Store at 20°F to 110°F  temperature for NFPA Class II.
  • Store at 70°F to 95°F  temperature for NFPA Class III B.

*Reclassed based on container size and physical properties.

Pot Life

About 30 minutes. Working time depends on temperature and method of application. Working time for spray applications will be significantly shorter.