company tower banner
Chase Corporation Company Logo
CIM® 500 is a tough, durable, waterproofing coating specifically formulated to meet the demands of waterproofing for buried, non-UV exposed, or below grade applications. This two-component, liquid applied urethane coating adheres to most materials to form a permanent, seamless barrier to water. It is especially well suited for plaza decks, areas with multiple penetrations and curbs, and between-slab waterproofing.

Product Type: 2K (2 component) Coating

Features: Excellent Coating Performance, Good Toughness, Water Resistant

Compatible Substrates & Surfaces: Concrete, Glass, Metal, Steel, Wood

Application Method: Roller, Trowel

Technical Data Sheet
  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Features & Benefits

Advantages
  • Cold, liquid applied, self-leveling coating 
  • Self-adheres to most materials used in construction 
  • Easily applies to complex areas including penetrations and curbs 
  • Durable; withstands foot traffic 
  • Complies with the toughest VOC regulations
  • Self-flashing; saving time and materials at transitions
Product Highlights
  • CIM 500 is a tough, durable membrane specifically formulated to meet waterproofing demands in a buried and non-UV exposed application.
  • It adheres to most materials to form a permanent, seamless barrier to water.
  • It is well suited for plaza and podium decks, curbs, and areas containing multiple penetrations or irregular shapes, as well as split-slab applications.
  • Available in both a vertical and horizontal grade.

Applications & Uses

Application Method
Compatible Substrates & Surfaces
Surface Preparation

General

  • Substrates must be clean and surface dry with no oils, grease or loose debris.
  • Perform adhesion tests to confirm adequacy of surface preparation.

Concrete

  • Use of CIM epoxy primer is recommended to limit outgassing and maximize adhesion
  • The substrate must be clean, surface dry and free of contaminates.

Steel

  • SSPC-SP6 / NACE No. 3 Commercial Blast.

Other Metals

SSPC-SP1 solvent clean and abrasive blast to roughen and degloss the surface..
Wood

  • Substrate must be clean, dry and free of surface contamination.
  • Use of CIM epoxy primer is recommended to limit outgassing and maximize adhesion.

Glass

Thoroughly clean. CIM VOC Compliant Bonding Agent must be used for proper adhesion.

Previous Coatings and Linings

CIM 500 may be applied over some existing coatings and linings. Perform adhesion tests to confirm adequacy of surface preparation. CIM VOC Compliant Bonding Agent can be used to achieve higher adhesion properties. C.I.M. Industries does not accept responsibility for determining the suitability of an existing coating or lining as a substrate for CIM products. Owner shall perform adhesion tests on any existing coating or lining to determine suitability.

Earth : Use CIM Scrim

UV Exposure

CIM 500 is not designed for long term UV exposure, exposure should be limited to no longer than 180 days.

Temperature Conditions

Surface should be at least 50°F (10°C) and must be 5°F (3°C) above the dew point. Do not apply when the substrate or ambient temperature is rising or the applied coating is in direct sunlight. CIM 500 should be at least 50°F (10°C) when mixed and applied. CIM 500 may be preheated to facilitate application at low temperatures however working time will be reduced. 

Mixing

DO NOT THIN. DO NOT HAND MIX. Begin mixing each pail of CIM 500 Premix using a power mixer (e.g., 1/2” drill and an eight-inch mud mixer). Do not draw air into the mix. The premix and activator are packaged and supplied in the proper mix ratio. Failure to mix CIM 500 as provided will result in off-ratio or uncured coating. While mixing, slowly add one full jug of CIM 500 Activator to one full pail of CIM 500 Premix. Mix thoroughly for 3 full minutes. Mixing Jigs and Timers are available from C.I.M. Industries to help eliminate mixing errors and increase productivity on the job.

Application

Apply CIM 500 directly to a clean and dry substrate. Vertical surfaces will require the use of CIM 500 Vertical Grade (VG) to achieve 60 wet mils in one application.

Equipment

Suitable for application with a roller, brush, squeegee, trowel, or spray equipment. Spray equipment requires large diameter hose and air supplied mastic gun. Airless pump may be used to provide fluid side pressure. 

Working Time

Working time depends on temperature and method of application, typically 35-45 minutes. Working time for spray application requirements will be significantly shorter.

Priming

Porous substrates such as wood and concrete may be primed with CIM epoxy primer to minimize outgassing. CIM 500 must be applied within 48 hours of primer application.

Recoating

If multiple coats are needed to achieve 60 wet mils, CIM 500 should be recoated as soon as practical, typically within 2 hours from mixing. If the coating has cured longer than this, the
surface must be severely abraded using surface grinder or other mechanical means. The surface must be made free of dust and debris and then use CIM VOC Compliant Bonding Agent before applying the CIM 500.

Recommended Minimum Thickness

The recommended minimum thickness of the coating is 60 wet mils. 

Curing Time

Curing Time Typically, CIM 500 can be placed in service within 24-48 hours. 

Clean-up

Use mineral spirits for clean-up of uncured material. Spray equipment must be flushed regularly during application to prevent material from setting up in the hose and pump. Cured material is very difficult to remove. Soaking in solvent will soften the material and may assist in its removal. 

 

Properties

Typical Properties
ValueUnitsTest Method / Conditions
Solids by Volume (Mixed (1460 mil x sq ft/gal))91.0%-
VOC97 (0.8)g/l (lb./gal.)-
Abrasion Resistance (Loss)max. 5mgASTM D4060 CS-17 Wheel, 1000 rev
Adhesion to Concrete (Dry)min. 350psiASTM D7234
Deflection Temperature (Minimum Use Temperature)max. -20ºFASTM D648
Density Premix8.9Ibs./gal.-
Density Activator10.1Ibs./gal.-
Density Mixed & Cured9.3Ibs./gal.-
Elastomeric WaterproofingExceeds all criteria-ASTM C836
Elastomeric WaterproofingExceeds all criteria-ASTM C957
Extension to Break200.0%ASTM D412
Hardness70.0Shore AASTM D2240 at 77ºF
Liner Performance (Crack Bridging 10 cycles at -15ºF)min. 1/8
Liner Performance (Crack Bridging After Heat Aging)min. 1/4
Liner Weight (60 mil wet film thickness)38.2lbs./100 sq. ft.-
Mix Ratio Weight9.4:1--
Mix Ratio Volume10.8:1--
Permeability to Water Vapor0.03permsASTM E96 Procedure B,100 mil sheet
Recovery from 100% extension (After 5 minutes)min. 90%-
Recovery from 100% extension (After 24 hours)min. 95%-
Service Temperature-20 to 180ºF-
Softening Point, Ring & Ballmin. 275ºFASTM D36
Tear Strength140.0lbs./in.ASTM D624 (Die C)
Tensile Strength700.0psiASTM D412,100 mil sheet
Flash Point Premix101.0ºF-
Flash Point Activatormin. 400ºF-

Safety & Health

Precautions

Avoid contamination with water or moisture. Keep all pails and jugs tightly closed until ready for use. All equipment, air supplies, and application substrates must be ABSOLUTELY DRY. Do not apply in wet weather or when the CIM 500 or substrate may become wet within 6 hours after application. Use caution when applying CIM 500 in confined spaces

Safety Information

Adequate health and safety precautions should be observed during storage, handling, application and curing. 

Warning :  Flammable. Use only in well ventilated areas. Do not store or use near open flame, sparks or hot surfaces. Keep tightly closed. Avoid contact with moisture or water. Keep out of reach of children. 

Packaging & Availability

Packaging

CIM 500 is available in 5-gallon ready to mix kits. Each kit consists of a container of premix and a smaller container of activator. The kits are supplied in the proper mix ratios with sufficient room in the premix container to facilitate adequate mixing. 

Storage & Handling

Shelf Life
18 months (Activator), 2 years (Premix)
Storage
  • Store at 20°F to 110°F  temperature for NFPA Class II.
  • Store at 70°F to 95°F  temperature for NFPA Class III B.

* CIM 500 Premix can be shipped as Not Regulated for most ground shipments.