CIM 800 is specifically formulated to meet the demands of today’s waterproofing market. This tough urethane coating offers exceptional performance
- Liquid applied and self adhering to most materials used in roofing construction.
- Tested to ANSI 118.10-199, “Standard Specification for Load Bearing, Bonded, Waterproof
- Membrane for Thin-Set Ceramic Tile and Dimension Stone Installation”.
- Can be applied to complex areas with multiple penetrations and curbs.
- Coating is tough enough to stand up to normal pedestrian traffic.
- Environmentally sound, complying with the toughest VOC standards.
- Accepts aggregate toppings as an integral part of the system for color, texture, traction, and added UV resistance.
- An excellent gutter material.
- Self flashing
- Product Highlights
CIM 61TN epoxy primer is a two-component, high solids, epoxy coating:
- Used as a primer for porous and non-porous surfaces such as concrete and metal
- ANSI/NSF 61 approved for potable water contact up to 82°C.
Applications & Uses
- Markets
- Surface Preparation
General
- Substrates must be clean and surface dry with no oils, grease or loose debris.
- CIM Bonding Agent is recommended on all non-porous substrates.
- Perform adhesion tests to confirm adequacy of surface preparation.
Concrete
- ICRI-CSP 4-6 surface profile exposing aggregate.
- Concrete must exhibit minimum 3,000 psi compressive strength and be free of release agents and curing compounds.
- The substrate must be clean, surface dry and free of contaminates.
Steel
- Minimum 3 mil profile.
- Non-Immersion service – SSPC-SP6 / NACE No. 3 Commercial Blast.
- Use CIM Bonding Agent for greater adhesion.
Other Metals
SSPC-SP1 solvent clean and abrasive blast to roughen and degloss the surface.
Glass
Thoroughly clean. CIM Bonding Agent must be used for increased adhesion.
WoodSubstrate must be clean, surface dry and free of surface contamination.
Previous Coatings and Linings
CIM 800 may be applied over some existing coatings and linings and achieve acceptable performance. CIM Bonding Agent is recommended for greater adhesion. Finished
system results vary due to a variety of project specific factors, including the service conditions to which the system is exposed. Therefore, C.I.M. Industries does not accept
responsibility for determining the suitability of an existing coating or lining as a substrate for CIM products. Owner shall perform adhesion tests on any existing coating or lining to
determine suitability.Earth : Use CIM Scrim
Color
CIM 800 is initially shiny black, turning dull over 3 to 6 months when exposed to direct sunlight. For a colored or reflecting surface finish,
- Temperature Conditions
Surface should be at least 50°F (10°C) and must be 5°F (3°C) above the dew point. Do not apply when the substrate or ambient temperature is rising or coating is in direct sunlight. CIM 800 should be at least 50°F (10°C) when mixed and applied. CIM 800 may be preheated to facilitate application at low temperatures, but working time will be reduced. See C.I.M. Industries’ Instruction Guide “Applying CIM Coatings in Cold Weather” (IG–11).
- Mixing
DO NOT THIN. DO NOT HAND MIX. Begin mixing each pail (4.5 gal.) of CIM 800 Premix using a power mixer (e.g. 1/ 2” drill and an eight inch mud mixer). Do not draw air into the mix. While mixing, slowly add one jug (0.5 gal.) of CIM 800 Activator to the pail and mix thoroughly for 3 FULL MINUTES. The proportions are pre-measured. DO NOT ESTIMATE. Mixing Jigs and Timers are available from C.I.M. Industries to help eliminate mixing errors and increase productivity on the job. See C.I.M. Industries’ Instruction Guide, “Mixing CIM Premix and Activator” (IG–8).
- Application
Apply CIM 800 directly to a clean and dry substrate. Vertical surfaces will require multiple coats.
Equipment
Spray equipment requires large diameter hose and air supplied mastic gun. Airless pump may be used to provide fluid side pressure. Roller, squeegee and trowel may also be used.
Priming
Porous substrates such as wood and concrete may be primed with CIM Epoxy Primer to minimize outgassing. The maximum recoat window for CIM Epoxy Primer is 48 hours.
Recoating
CIM 800 may be recoated in 1 hour and must be recoated soon after the coating no longer comes off on polyethylene (typically within 4 hours of mixing). If the coating has cured longer than this time, the surface must be severely abraded using surface grinder or other mechanical means, and be free of dust and debris. Use CIM Bonding Agent for better adhesion.
Recommended Minimum Thickness
Recommended minimum thickness of the coating is 60 wet mils.
Curing Time
Typically, CIM 800 can be placed in service within 24-48 hours.
Clean-up
Use mineral spirits for clean-up of uncured material. Spray equipment must be flushed regularly during application to prevent material from setting up in the hose and pump. Cured material is very difficult to remove. Soaking in solvent will soften the material and may assist in its removal.
Properties
- Typical Properties
Value | Units | Test Method / Conditions | |
Solids by Volume (1448 dry mils x sq. ft./gal.) | 90.0 | % | - |
VOC | 95 (0.80) | g/l (lb./gal.) | - |
Abrasion Resistance (Loss) | 1.2 | mg | ASTM D4060 Taber Abraser CS-17 Wheel, 1000 gr./1000 rev. |
Adhesion to Concrete (Dry) | 350.0 | psi | Elcometer |
Deflection Temperature (Minimum Use Temperature) | max. -40 | ºF | ASTM D648 |
Density Premix | 8.0 | Ibs./gal. | - |
Density Activator | 10.1 | Ibs./gal. | - |
Density Mixed & Cured | 8.5 | Ibs./gal. | - |
Elastomeric Waterproofing | Exceeds all criteria | - | ASTM C836 |
Elastomeric Waterproofing | Exceeds all criteria | - | ASTM C957 |
Extension to Break | 400.0 | % | ASTM D412 |
Flammability | Pass/combustible substrate | - | ASTM D2859 |
Flammability | Class A1 | - | UL790 |
Flooring and Shower Lining | Pass | - | UPC/IBC ANSI 118.10 |
Green Roof Membrane/Root Barrier | Pass | - | ANSI/GRHC/SPRI VR-1 2011 |
Hardness | 60.0 | Shore A | ASTM D2240 at 77ºF |
Liner Performance (Crack Bridging 10 cycles at -15ºF) | min. 1/8 | ” | |
Liner Performance (Crack Bridging After Heat Aging) | min. 1/4 | ” | |
Liner Weight | 37.8 | lbs./100 sq. ft. | - |
Mix Ratio Weight | 7.7:1 | - | - |
Mix Ratio Volume | 9.6:1 | - | - |
Mullen Burst Strength | 100.0 | psi | ASTM D751, 50 mil |
Permeability to Water Vapor | 0.03 | perms | ASTM E96 Method E, 100ºF,100 mil sheet |
Recovery from 100% extension (After 5 minutes) | 98.0 | % | - |
Recovery from 100% extension (After 24 hours) | 100.0 | % | - |
Service Temperature | -60 to 180 | ºF | - |
Softening Point, Ring & Ball | 275.0 | ºF | ASTM D36 |
Tear Strength | 115.0 | lbs./in. | ASTM D624 (Die C) |
Tensile Strength | 800.0 | psi | ASTM D412,100 mil sheet |
Flash Point Premix | 101.0 | ºF | - |
Flash Point Activator | min. 400 | ºF | - |
Regulatory & Compliance
- Certifications & Compliance
Safety & Health
- Precautions
Avoid contamination with water or moisture. Keep all pails and jugs tightly closed until ready for use. All equipment, air supplies, and application substrates must be ABSOLUTELY DRY. Do not apply in wet weather or when rain is imminent or when the CIM 800 or the substrate may become wet within 4 hours after coating. Use caution when applying CIM 800 in confined spaces.
- Safety Information
This product contains petroleum asphalt, petroleum distillates, amine compounds and/or other chemical ingredients. Adequate health and safety precautions should be observed during storage, handling, application and curing.
Warning Flammable : Use only in well ventilated areas. Do not store or use near open flame, sparks or hot surfaces. Keep tightly closed. Avoid contact with moisture or water. Keep out of reach of children.
Packaging & Availability
- Packaging
CIM 800 is available in mixed units of 5 gallons. Each unit consists of a container of premix and a smaller container of activator. Quantities have been premeasured to provide the proper mixing ratio, leaving sufficient room in the premix container to facilitate adequate mixing. Do not estimate proportions.
Storage & Handling
- Shelf Life
- 1 year (Activator), 2 years (Premix)
- Storage
- Store at 20°F to 110°F temperature for NFPA Class II.
- Store at 70°F to 95°F temperature for NFPA Class III B.
* Reclassed based on container size and physical properties,
- Pot Life
About 45 minutes. Working time depends on temperature and method of application. Working time for spray application requirements will be significantly shorter.