Knowde Enhanced TDS
Identification & Functionality
- Technologies
- Product Families
Features & Benefits
- Labeling Claims
- Ready-to-Use Product Features
- Advantages
- Water based cleaner.
- General purpose product, useful over a wide range of applications.
- Excellent rinsability.
Applications & Uses
- Markets
- Applications
- Application Area
- Application Method
- Compatible Substrates & Surfaces
- Normal Use
This product is diluted with water before use. Determine the proper ratio based on the volume of the tank. Mix MC 690 LF 1 to 10% with water (2 to 5 % typical).
Properties
- Typical Properties
Value | Units | Test Method / Conditions | |
Concentration | 5 - 20 | % | — |
Operating Temperatures | 110 - 160 | °F | — |
pH Value | 2 - 3 | — | — |
Technical Details & Test Data
- Normal Control
Dropping Bottle Method (Test Kit available from Chautauqua Chemicals Co. -Part No. 3647)
- Take a sample of the MC 690 LF solution from the bath with a beaker and allow to cool to room temperature.
- Measure out 5 ml using the graduated sample bottle provided in the test kit.
- Add 1 drop of phenolphthalein indicator.
- Add dropwise 2.4N sodium hydroxide while counting the drops and swirling the solution.
- Stop adding the drops when color changes from colorless to pink.
- Calculation: Percent Concentration of MC 690 LF = Drops of 2.4N NaOH x 0.35