company tower banner
Chemproof Polymers Company Logo
PERMATEC 5000 floor topping is a 100% solids, unique blend of polymers with an epoxy novolac base. The PERMATEC 5000 system consists of a two component resin binder and graded aggregate. It is applied with a trowel or screed rake at 1/8 -1/4 inches (125 - 250 mils) in a one coat application including a silica broadcast. There is no need for a primer or sealer coat. An optional glaze coat may be used to improve the appearance and cleanability. The vertical formulation of PERMATEC 5000 is trowel applied at 1/8 inches (125 mils).

Product Type: 2K (2 component) Coating, Solventless & High Solids Coating

Compatible Substrates & Surfaces: Concrete

Features: Chemical Resistant, Fast Cure, Skid Resistant, Wear Resistant

Technical Data Sheet
  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Features & Benefits

Labeling Claims
Features
  • PERMATEC 5000 is a 100% solids system and allows for a fast application where outstanding chemical and wear resistance are required.
  • PERMATEC 5000 can be installed over most sound floors including old or new concrete and most types of repair mortars.
  • At varying thicknesses up to 1/4 inches, the PERMATEC 5000 system provides long term chemical resistance for splash and spill, or immersion in a wide range of chemicals.
  • PERMATEC 5000 is similar to PERMATEC 3000 & 4000 but provides a higher degree of chemical resistance to concentrated acids, caustics and solvents.
  • As with all PERMATEC systems, PERMATEC 5000 provides excellent physical protection even in the harshest industrial settings.
  • Rapid cure resulting in minimal downtime.
  • 100% non-porous
  • Odor free
  • Non-skid safety finish
  • Can be applied over damp concrete.

Applications & Uses

Compatible Substrates & Surfaces
Functions

The primary use of PERMATEC 5000 is as a high strength floor topping for industrial service where severe mechanical abuse and/or chemical exposure is anticipated.

Typical Applications
  • Process floors
  • Containment basins
  • Trenches
  • Sumps
  • Tank bases
  • Any area in general where harsh chemicals are used.
Cure Time
  • The cure time of PERMATEC 5000 and other resinous systems are very dependent upon the temperature of the substrate.
  • The ambient temperature may not be the same as the substrate temperature. For example, during winter concrete may be colder than the surrounding ambient temperature.
  • As temperatures during the day may increase, large masses of concrete will be much slower to react.
  • During summer days direct sunlight will increase the concrete temperature over that of ambient air.
  • The substrate temperature should be monitored and remain at or above 65°F.
Service (Hours) 65F 75F 90F
Foot traffic 10 7 4
Light Chemical 12 10 10
Fork Lift 24 10 8

*Where heavy chemical abuses are anticipated, longer cure times may be required.

Surface Preparation
  • New Concrete - The concrete should be well cured for a minimum of 10 (ten) days, per ACI 308- 81, (R-1986), clean, dust-free and free of all contaminants. Mechanical methods such as sandblasting, scarifying or shot blasting should be employed to remove the weak layer of surface laitance. A minimum tensile strength of 200 psi is required of the prepared surface. Acid etching with muriatic acid is acceptable but less desirable. Care must be taken to completely remove all residual acid prior to the application of PERMATEC 5000.
  • Existing Concrete - Concrete must be structurally sound and free of all contaminants. Weak or contaminated concrete must be removed until sound concrete is realized. Old coatings, toppings, waxes, oils, etc. must be removed prior to the application of PERMATEC 5000.
Mixing
  • Prior to application, the PERMATEC 5000 (Resin, Hardener and Silica) and the substrate should be between 65°F and 90°F.
  • In order to maintain a clean mixer from batch to batch, the Resin (Part A) and a portion of the Silica (Part C) should be added to the mixer and agitated long enough to clean the blades.
  • Add the Hardener (Part B) only when the batch is ready to be applied.
  • Mix for approximately 30 seconds - 1 minute, then add the remainder of the Silica and mix for another 90 seconds.
  • Pour immediately onto the floor.
Product Application

Permatec 5000 can be applied as follows:

  • Application thickness may vary from 1/8 to ¼ inches, depending on the expected service conditions.
  • Factors to consider are length of chemical exposure (i.e. immersion vs. splash/spill) and mechanical abuses (i.e. tow traffic, loaded trucks vs. cart and foot traffic, etc.). Some applications may not require a 1/8 or 1/4 inch floor topping (i.e. secondary containment, many vertical applications, etc.)
  • A self-leveling tendency will be noticed after the material has been poured on the surface to be coated.
  • However, some assistance is required in order to achieve the specified thickness. Conventional hand troweling and screed raking are the two recommended methods of application.
  • Screed raking is generally preferred because of the uniformity in thickness that can be achieved.
  • A Silica broadcast is required for proper filling of the system and for skid resistance.
  • The surface should be saturated and the excess removed after the material has set.

PERMATEC 5000 should not be applied over substrates:

  • Subject to extreme hydrostatic pressure.
  • Which are unsound.
  • Which are contaminated and cannot be cleaned.
  • At temperatures below 65°F.

Properties

Typical Properties
ValueUnitsTest Method / Conditions
Solids (Volume)100.0%
Compressive Strength14000.0psiASTM C579
Flexural Strength5500.0psiASTM D790
Tensile Strength2200.0psiASTM D307
Taber Abrasion (CS 17 Wheels, Loss/1000 Cycles, w/1000 gms)25.0mgASTM D4060
Bond Strength to ConcreteExceeds Tensile Stregth of ConcreteASTM D4541
Water Absorption0.1%ASTM D413

Safety & Health

Safety

PERMATEC 5000 contains blended epoxies as the resin and blended amines as the hardener. Protective clothing and gloves are recommended to prevent sensitization to these materials. In case of ingestion or eye contact, it is advisable to contact a physician immediately.

Packaging & Availability

Packaging

PERMATEC 5000 is available in 20, 100, and 1000 square foot units based on 1/4 inch applications. Each unit consists of pre-measured components, Part A (Resin) and Part B (Hardener). Graded aggregates are available or may be sourced locally.

Storage & Handling

Storage & Shelf Life

PERMATEC 5000 should be stored at 50 - 90 °F out of direct sunlight. All containers should remain unopened until ready for use. If stored as set out above, PERMATEC 5000 has a minimum shelf life of one year.