Childers® CHIL-FLEX™ CP-146 is a water-based duct sealant developed for use in all heating, ventilating and air-conditioning metal ductwork systems. It is easily applied, and its metallic gray color blends well with ductwork

Product Type: Waterborne Adhesive

Compatible Substrates & Surfaces: Metal

Application Method: Brush, Trowel

  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Features & Benefits

Advantages
  • Water-based for personal & environmental safety.
  • Application is quick & easy for economical installation.
  • Dries firmly & forms a strong, resilient seal.
  • Creates a permanently flexible seal (even when system cycles between high and low temperatures).
  • Resistant to fire, oxidation, cracking, moisture & water.
  • Long service life.
  • Quick & efficient clean up of tools & metal with hot water when sealant is still wet.

Applications & Uses

Application Method
Compatible Substrates & Surfaces
Uses

Childers® CHIL-FLEX™ CP-146 is used to seal all metal joints in high, medium and low pressure air handling ductwork systems. Application by trowel, brush or extrusion readily fills the joints of round, rectangular, rigid or flexible ductwork, diffusers and mixing boxes.

Limitations
  • Store and apply between 40ºF (4ºC) and 100ºF (38ºC); protect from freezing.
  • To resist rain washoff, allow at least 16 hours drying time above 40ºF (4ºC), with a relative humidity of 50%. Higher humidity or lower temperatures may retard drying.
  • Always test foil and paper facings for acceptable adhesion.
  • Outdoor horizontal surfaces must always drain completely. A pitch of at least 1/4 inch per foot (2 cm/m) is required.
  • If used between two impermeable surfaces, drying time will be extended.
Material Preparation

All surfaces where sealant will be applied must be clean, dry, and free of oil or grease prior to application.Do not thin. Keep container closed when not in use.

Application

Ul 181B Mastic Closure Of Ul 181 Flexible Air Ducts:

Apply to clean, dry, oil-free surfaces by brush, trowel, or power extrusion. Brush CP-146 out uniformly in a 2” wide coat over the joint at the nominal rate of 2 gal./100 sq. ft. (0.8 l/m2). Total coverage rate to be 45 – 55 sq. ft./gal (1.1 – 1.4 m2/l). Allow the completed joint to dry at least 24 hours above 70ºF (21ºC) before pressure testing. High humidities (over 70%) and/or cooler temperatures may retard drying. Total wet film thickness to be 32 mils ± 3 mils.
 

Other Sealing Applications – Not Ul 181:

Apply a continuous film of CP-146 Duct Sealant over all areas of the indoor or outdoor duct system where air leakage may occur. A brush may be used to work the sealant into joints and remove excess. On spiral ducts, apply a coat of CP-146 to the male end of the coupling prior to fitting the straight run of spiral duct over it. Brush excess CP-146 over the joint to complete the seal. Screw holes and flanges should also be sealed with a coat of CP-146. They may be applied to the inside or the outside of the duct.

Top Coating:
After it is completely dry, CP-146 may be top coated with good quality water-based paint.

Power Extrusion:
CP-146 Duct Sealant may be applied using a wide variety of power (pressure) extrusion equipment suitable for use with water-based sealants. It is a soft buttery gel with a typical viscosity range of 130,000 – 180,000 cps. Corrosion resistant pumps and fittings are suggested.

Top Coating

After it is completely dry, Childers® CHIL-FLEX™ CP-146 may be top coated with good quality water-based paint.

Clean Up

Use fresh water to clean brushes and equipment before product dries. Dry product may be removed with hot soapy water or strong solvents such as chlorinated solvent (non-flammable) or xylol (flammable).

Properties

Color
Typical Properties
ValueUnitsTest Method / Conditions
Average Non Volatile (By Weight)70.0%ASTM D2369
Clean UpWarm, soapy water (wet) or xylol (dry)
Coverage (Dependent on Substrate, Film Thickness and Machine Settings)40.0sq. ft./U.S. gal.
Drying Time (Through)16-24Hours
Drying Time (To Touch)2.0Hours
Fungal Resistance0.0ASTM G21
Service Temperature Range (Temperature to which dry adhesive is subjected.)20-200ºF
Shore Hardness (Type A)72.0ASTM D2240
Water vapour Permeance (at 0.031 in. dry film thickness)0.5 – 1.3perms ASTM F1249
Wet Weight 11.7lbs./U.S. gal.ASTM D1475

Regulatory & Compliance

Certified
  • MAS Certified Green®
  • California Dept. of Public Health Standard Method v1.2
  • VOC Emissions and Content requirements to contribute to Leed v4 EQ Credit: Low Emitting Materials – Paints and Coatings
  • VOC Content: 24 g/l, less water and exempt solvents
  • Collaborative for High Performance Schools EQ 7.1
  • CP-146 Duct Sealant is produced under the classification and follow-up service of Underwriter’s Laboratories, Inc. and meets NFPA 90A and 90B 25/50 requirements
  • CP-146 meets all SMACNA pressure classes up to 10" w.g. and SMACNA seal classes A, B and C on ducts constructed to SMACNA standards. It has been tested up to 15" w.g. and passed with no sealant blow out
UL 181B-M Listed Control No. 6P84

Childers chil-flex™ sealant is listed by underwriters laboratories, inc. Under standard 181b, mastic closure of ul 181 flexible air ducts.

Technical Details & Test Data

Surface Burning Test Characteristics ASTM E84

Applied to Inorganic Reinforced Cement Board

 
Flame Spread 0
Smoke Developed 0

 

Tested as applied in two 2 in. wide strips spaced 8 in. on center at a coverage rate of 45 sq. ft./gal.