CIMSTAR® QUAL STAR XL is a metalworking fluid that is semi-synthetic. It is a chlorine-free general-purpose machining and grinding fluid.

Application Area: Boring Applications, Drilling Applications, Machining Operations, Milling Operations, Reaming, Sawing Operations

Compatible Substrates & Surfaces: Magnesium, Metal, Steel

Features: Corrosion Resistant, General Purpose, Microbe Resistant, Stain Resistant

Metalworking Fluid Type: Semi-Synthetic

Technical Data Sheet
  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Base Oil Type
Metalworking Fluid Type

Features & Benefits

Labeling Claims
Features and Benefits

Versatile Product:
This New Generation Bio-stable Semi-synthetic Blends The Technical Advantages Of Modern Day Synthetics Fluids With The Performance Of Soluble Oils. Because Of The Unique Formulation, This Product Can Be Used On Tough Applications Like Sawing But Also Versatile Enough For Surface Grinding, Milling Or Turning.
Corrosion Protection:
The Oily Residue Keeps Machine Tools And Work-piece Materials Free Of Corrosion And Staining.
Microbial Control:
CIMSTAR® QUAL STAR XLHas Excellent Rancidity Control.
* CIMSTAR® QUAL STAR XLB Has The Same Performance Characteristics As Cimstar Qual Star Xl But Has Additional Foam Control.

Applications & Uses

Markets
Compatible Substrates & Surfaces
Applications

CIMSTAR QUAL STAR XL* was developed for use on ferrous and most non-ferrous materials. It can be used on mild steels, stainless steels, hardened steels, and most non-ferrous alloys. It should not be used on magnesium alloys.
For use in moderate duty machining and grinding applications, such as milling, drilling, cut tapping, reaming, boring and in most grinding applications.

Concentration

An MI Titration, Non-solvent Titration, Total Alkalinity or Refractometer can be used.
The Refractometer Factor is 1.7
Multiply the scale reading obtained on your CIMCOOL® Refractometer by this factor to obtain the mix concentration in percent. Calibrate the refractometer so that it reads 0.0 with water before testing the sample mix. Remove gross contaminants from the sample mixes before testing. A refractometer is only recommended for use in checking the concentration of a fresh charge.

Properties

Physical Form
Appearance
Hazy
Odor
Chemical
Solubility in Water
100% Miscible
Typical Properties
ValueUnitsTest Method / Conditions
Viscosity (SUS, 100°F)450.0
pH Concentrate10.0
Total Chlorine0.0ppm
SiliconesNo For Cimstar Qual Star Xl / Yes For Cimstar Qual Star Xlb
Weight (60°F, 15.6 °C)8.5Ib/gal
Chloridemax. 50ppm
pH Mix 5% (Typical Operating)8.8
Total Sulfur0.4wt%

Technical Details & Test Data

Recommended Starting Dilutions

CIMSTAR QUAL STAR XL is to be mixed with water for use. Always add concentrate to water. Fluid may be more difficult to mix when water temperature is below 55 F (13 C). Add no other materials to the concentrate or mix unless approved by your CIMCOOL® District Manager.
Grinding 5% - 10% (1:20 to 1:10)
Machining 5% - 10% (1:20 to 1:10)

Storage & Handling

Handling and Storage