Knowde Enhanced TDS
Identification & Functionality
- Technologies
- Product Families
Features & Benefits
- Ready-to-Use Product Features
- Features
- Excellent hardness, scratch resistance and chemical resistance even at cure temperatures as low as 130°C.
- Non-yellowing even on over bake at 190°C.
- Excellent clarity and flow maintained without solvent addition.
- Resistance to Chemicals
CLEARCLAD LC408 has excellent resistance to normal household products and many commonly used industrial chemicals.
Applications & Uses
- Application Area
- Application Method
Properties
- Physical Properties
- Environmental Properties
- Typical Properties
Value | Units | Test Method / Conditions | |
Resistance to Perspiration (depending on cure schedule) | max. 4 | Cycles | ANSI/BHMA |
Pencil Hardness (at 3 newtons) | 5 - 6 | H | ASTM D3363 |
Abrasion Resistance Coefficient (with Ottawa sand) | 25.0 | lit/mil | ASTM D968 |
Normal Coating Thickness Range (depending on application specification) | 10 - 25 | microns | — |
Acetone Rub Test for Cure | Pass (1000 double rubs) | — | — |
Adhesion (1mm cross cut with tape pull) | Pass (100%) | — | — |
Flexibility (Conical Mandre) | Excellent | — | — |
Impact (Direct and Reverse) | Excellent | — | — |
Scratch Resistance | 1.5 | Newtons to mar | Erichsen 318 |
Value | Units | Test Method / Conditions | |
Salt Spray (can be achieved depending on substrate and pretreatment) | 200 - 2000 | Hours | ASTM B11 |
Ultraviolet Light (with no loss of decorative aspect.) | 500.0 | Hours | ASTM G53 |
Mass Loss | max. 5 | mg/dm² | — |
Humidity | Excellent | — | — |
Value | Units | Test Method / Conditions | |
Solids Content (120°C for 1hr) | 45 - 50 | % w/w | Gravimetrically |
Technical Details & Test Data
- Technical Details
Bath Control
User determined parameters
Low High Optimum Solids w/w: 8 10 9 MEQ corrected: 30 35 33 Solvent A264 w/w: 2 7 3.0 - 4.0 Temperature °C (°F): 23° (73°) 29° (84°) 26° (79°) Bath Control - Derivative parameters
- Conductivity ms/cm: Recommended range 400 - 600
- pH (instrumental): Normal range 3.6 - 4.4
Note: New baths should be conditioned for 24 - 48 hours before use. At least one bath volume of UF permeate should be eliminated during this conditioning period. The MEQ and solvent content should be adjusted as necessary before commencing production.
Deposition Conditions
Depending on required thickness, 30 - 150 volts for 30 to 90 seconds
Curing Conditions
LC408 is able to cure at temperatures as low as 120°C. However, to exploit the enhanced chemical resistance it is practical to use 130°C for up to 60 minutes at metal temperature as a minimum temperature regime. Increasing the metal temperature up to 190°C will increase resistance properties without discoloration of the coating in correctly maintained ovens.
Packaging & Availability
- Packaging Information
Packaging is 20 liter American pails. Other packing types and sizes may be available on request.