CIPADAM® S-40 is a clear, penetrating, breathable sealer that contains a 40 percent solution of Silane in an alcohol carrier. CIPADAM S-40 chemically reacts with the concrete substrate and most masonry surfaces to produce a long lasting water repellent effect. This material's small molecular structure allows for maximum penetration into any siliceous material to form an alkali resistant polysiloxane.

Product Type: Sealer

Compatible Substrates & Surfaces: Concrete

Features: Alkali Resistant, Breathable, Efflorescence Control, Low VOC, Mildew Resistant, Stain Resistant, Water Resistant

Application Method: Spray

Chemical Family: Silanes

Similar Products

  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Chemical Family
Product Type

Features & Benefits

Labeling Claims
Benefits
  • Excellent resistance to water intrusion
  • Excellent resistance to chloride ion ingress
  • Breathable
  • No change in surface appearance
  • High resistance to alkali attack
  • Reduces the effects of efflorescence, mildew, and stains on vertical concrete and masonry structures
  • Meets the requirements of OTC (V.O.C. <350gm/L)

Applications & Uses

Application Method
Compatible Substrates & Surfaces
Used in
  • Parking garages
  • Building envelopes
  • Ramps and other concrete and masonry structures
Surface Preparation
  • Caulking and patching materials must be fully cured before applying CIPADAM® S-40
  • All substrates must be properly cleaned and free of dust and contaminants before the application of the sealer
  • Acceptable surface cleaning methods include shot blasting, sand blasting, or water blasting
  • Usually no preparation is required for building envelopes unless the substrate has surface dirt or contaminants on it
  • Do not apply to a wet substrate, although a damp substrate may be treated
  • If a chemical curing agent has been used during installation of new concrete, it must be removed prior to the application of the sealer
Application
  • CIPADAM® S-40 should be applied as packaged - do not dilute or alter material
  • Preferred method of application is with low pressure (20 psi) airless spray equipment or with heavily saturated brush or roller
  • Sprayer should be fitted with solvent resistant hoses and gaskets
  • When using brushes or rollers, care should be taken to ensure that enough solution is applied
  • Apply sufficient material to thoroughly saturate the surface making sure to brush out excess material that does not penetrate
Horizontal Surface Applications
  • This product should be applied in a single saturating application with sufficient material so that it should pond on the surface at least 5 seconds before being absorbed
  • Surface residues, pools and puddles should be broomed out thoroughly until they completely penetrate into the surface
  • Protect from vehicular traffic for 24 hours
Vertical Surface Application
  • This product should be applied in a flooding application from the bottom-up so the material runs down 15-20 cms (6"-8") below the spray pattern
  • On porous substrates, this product should be applied in two "wet-on-wet" applications
  • Allow the first application to penetrate the surface and re-apply in the same manner
Limitations
  • Not intended for below-grade waterproofing
  • It can be applied at temperatures down to -7°C (20°F) provided no ice or frost exist in or on the surface
  • Do not apply if the ambient temperature of the surface exceeds 38°C (100°F)
  • Do not apply if rain is expected within 4 hours
  • If rain has preceded the application, the surface should be allowed to dry for at least 24 hours
  • This material should be stored in sealed containers and kept away from extreme heat
Coverage
  • Porosity and texture of the concrete and masonry surface will affect the amount of material necessary for effective treatment
  • Always test on the actual surface to get precise consumption rates
  • Concrete: 3-7m²/L (120-285 ft²/U.S. gal.) depending on porosity
Clean up

Clean up with CPD® Xylol

Properties

Color & Finish
Cear, Invisible
Typical Properties
ValueUnitsTest Method / Conditions
Active Substance Content (Weight)40.0%
Specific Gravity0.87
Flash Point (T.C.C.)4.4°C

Safety & Health

Precautions
  • This product contains blended solvents and alcohol should be handled accordingly
  • Do not use near fire or extreme heat and provide good ventilation to avoid buildup of solvent fumes
  • Applicators should wear approved NIOSH/MSHA approved respirators
  • When applying to exteriors of occupied buildings, all exterior air conditioning vents should be covered during application and air handling equipment should be turned off during application to avoid solvent odors within the building
  • Clothing which may become contaminated with CIPADAM® S-40 should be changed as quickly as possible
Maintanance

Chemical spills, salts and abrasives should be removed from the surfaces as soon as possible.

Packaging & Availability

Packaging Type
Packaging

208L (55 U.S gal) drum - 182kg (401lbs) / drum

18.9L (5 U.S gal) pail - 16.5kg (36.5lbs)/pail

3.79L (1U.S.gal) can 3.5Kg (7.7lbs) can

Storage & Handling

Storage
  • Contains flammable solvents. Keep away from open flame
  • Keep containers tightly closed when not in use
Shelf Life

Three years from date of manufacture when stored in original unopened container, and under normal warehouse conditions