Knowde Enhanced TDS
Identification & Functionality
- Technologies
- Product Families
Features & Benefits
- Labeling Claims
- Ready-to-Use Product Features
Applications & Uses
- Markets
- Application Method
- Application
CG 4555 is to be used straight, do not cut back with solvent or dilute with any other oils. CG 4555 is not water soluble, and will not mix with water.
Properties
- Typical Physical Properties
Value | Units | Test Method / Conditions | |
Fluid Type | Rust Preventative | - | - |
Specific Gravity | 0.9 | - | - |
Flash Point: | min. 395 | °F | - |
Viscosity (40 °F) | 70-65 | cSt | - |
ASTM Color | 3.0 | - | - |
Water Displacement | Pass | - | - |
Humidity Cabinet | 1,848 Hours | - | ASTM D 1748 |
Salt Spray (5%) | 36 Hours | - | ASTM B117 |
Acidic Atmosphere | Pass- Up to 24 hours. | - | - |
Nickel Metal Reactivity | No nickel reaction in laboratory, test in field | - | - |
Barium | Barium Free | - | - |
Application | Parts may be sprayed or dipped. | - | - |
Heavy Metals | No heavy metals in product | - | - |
Storage & Handling
- Shelf Life
- 2.5 Years (Indoor)
- Storage
CG 4555 should be stored at room temperatures (between 55 to 95 °F). Keep away from sparks, open flames, and other sources of ignition as product and empty containers could contain combustible, flammable, or ignitable substances. Do not weld or cut empty drums.