Knowde Enhanced TDS
Identification & Functionality
- Product Type
- Components
- 1
- Technologies
- Product Families
Features & Benefits
- Ready-to-Use Product Features
- Features & Benefits
- Butylseal 572 penetrates deeper into a porous substrate providing a better waterproof seal. Butylseal 572 provides greater adhesion for the elastomeric base coat. It applies easily with airless, conventional air, roller or brush, and its water-base allows for easy clean-up and low odor.
- Butylseal 572 primarily functions as a sealer over concrete, masonry, stucco and wood surfaces for Davlin's Acrylastic elastomeric waterproof wall and deck coatings.
Butylseal 572 is the foundation for
Deck System:
- Primer: Butylseal 572
- Base Coat: Acrylastic 490
- Top Coat: Sunshield 3800
Wall System
- Primer: Butylseal 572
- Base Coat: Acrylastic 600
- Top Coat: Sunshield 3800
Applications & Uses
- Applications
- Application Area
- Applications & Uses
Surface Preparation
- All surtaces shall be clean, free from dirt, release agents, wax, mildew and all other contaminants, including salt deposits.
- Concrete, masonry, stucco: Water clean by ASTM D4258-6.4. Water pressure should be between 1500-3000 p.s.i.
- Previously coated surface: Wire brush, scrape or water blast all areas where pre-coated surface is scaly, chalky or loose to remove all contamination.
Application Instructions
- Flush all equipment with water before use. Stir Butylseal 572 thoroughly until uniformly blended. Avoid excessive mixing to prevent air entrapment. Thinning is not recommended. Spray, Brush or Roll, saturating entire surface. Clean equipment with water or water and detergent immediately after use.
- Drying time to recoat @70°F: 4 hours (low humidity) to 8 hours (high humidity).
Application Equipmets
The following is a guide; suitable equipment from other manufacturers may be used. Changes in pressure and tip size may be needed for proper spray characteristics.
- Airless: Standard equipment such as Graco Series 600. Tip sizes from 0.018 0.021
- Conventional: Industrial equipment such as DeVilbiss, MBC or JGA spray gun. Separate air and fluid pressure regulators and a moisture and oil trap in the main air supply lines are recommended.
- Brush/Roller: Suitable for waterborne coating.
Properties
- Typical Properties
Value | Units | Test Method / Conditions | |
Coats | 1.0 | — | — |
Coverage per Gallon (Depends on Porosity of Surface) | 75 - 250 | Square feet pergallon | — |
Curing Mechanism | Air Dry | — | — |
Dry Film Thickness Per Coat | 2.0 | mils | — |
Flash Point (SETA) | min. 215 | °F | — |
Penetration | min. 1 | inch | No. 52 What-Man |
Percent Non-Volatile | 30.0 | % | — |
Recommended Total DFT | 2.0 | mils | — |
Viscosity | 52 - 58 | KU | — |
VOC | 7.0 | g/L | — |
Weight per Gallon | 8.5 | lbs/gal | — |