Knowde Enhanced TDS
Identification & Functionality
- Carrier
- Product Type
- Technologies
- Product Families
- Identification
Base: Water
Chemical Family: Synthetic Latex
Features & Benefits
- Labeling Claims
- Ready-to-Use Product Features
- Features & Benefits
- LEED V4 Qualified
- Low VOC
- Low Odor
- Resists Mold and Mildew Growth on the Coating Surface ASTM D-5590 and ASTM G21-15
- No Stirring or Straining
- Flexible and Durable
Applications & Uses
- Markets
- Application Area
- Compatible Substrates & Surfaces
- Recommended Uses
- May be used to coat bare metal supply, return, and transfer HVAC duct.
- May be used to coat faced or unfaced fiberglass duct liner and rigid fiberglass duct.
- May be used to repair fiberglass insulation and effectively control fiberglass erosion.
- May be used to edge coat or “butter” cut edges of fiberglass duct liner and rigid fiberglass duct.
- Directions for Use
Surface Preparation: Surfaces should be clean, dry and free of dirt, oil, and any foreign matter. For remediation applications, surface should be washed and sanitized with a high quality biocide and then thoroughly rinsed. Allow surfaces to dry completely. For painted surfaces, sand lightly to roughen substrate prior to cleaning. HVAC systems should be under negative air pressure during application. Circulate fresh air through the system to dry coating. Air should be odorless and filters replaced before venting into occupied areas.
Application: Fiberglass Application: May be applied by brush, roller, or airless sprayer. For damaged, unfaced or ductboard, apply at a rate of 75 sq. ft. per gallon. For undamaged faced fiberglass apply at a rate of 75 to 200 sq. ft. per gallon. Surfaces should be completely coated. Spray application should coat surface thoroughly and evenly with one application; apply second coat to porous or irregular surfaces. Brush or roller application requires two coats applied at a 90 degree angle. Allow first coat to dry before applying second coat. Metal Application: May be applied by brush, roller, or airless sprayer. No primer coat is required. Spray at a rate of 400 sq. ft. per gallon or apply by brush using the above instructions. Check small area for adhesion before coating metal, especially when coating stainless steel, aluminum and oiled steel.
Do not apply when rain or freezing temperatures will occur within 36 hours. Do not thin.
Clean Up: Use warm water and soap
Properties
- Color
- Typical Properties
Value | Units | Test Method / Conditions | |
Application Temperature | 40 - 110 | °F | — |
Coverage (On Non-Porous Surfaces, Metal) | 400.0 | sq. ft. | — |
Coverage (On Porous Surfaces Insulation) | 75.0 | sq. ft. | — |
Cure Time | 4 - 16 | Hour | — |
Flammability | Non-flammable Wet or Dry | — | — |
Flash Point | No Flash to Boiling | °F | — |
Freeze/Thaw Stability | Do not allow to freeze | — | — |
Service Temperature | -25 to 200 | °F | — |
Solids Content | 57 - 61 | % | — |
Storage Temperature | 40 - 110 | °F | — |
Viscosity | 4000 - 5000 | Cps | — |
VOC | 2.0 | g/l | — |
Regulatory & Compliance
- Certifications & Compliance
- Compliance
Meets Requirements of NFPA 90A & 90B, UL 723, and ASTM E-84
Packaging & Availability
- Packaging Type
- Packaging
1 gallon pail, 5 gallon pail
Storage & Handling
- Shelf Life
- 1 Year