company tower banner
DUNA-USA Company Logo

CORAFOAM® RP 40 HF

1 of 11 products in this brand
CORAFOAM® RP 40 HF is used as Polyurethane rigid foam PUR. can be cut with almost any type of tool. Its closed cellular structure and absence of fibers or granular structure result in crisp, excellently defined edges after fabrication. It is also impermeable by any type of liquid, including water and solvents, making it much better suited for severe weather conditions or harsh marine environments than many other materials.

Functions: Core Material

Core Type: Polyurethane Foam

Chemical Family: Polyisocyanurates, Polyurethanes (PU)

Technical Data Sheet
  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Composite Materials Functions

Features & Benefits

Applications & Uses

Blowing Agents

Pentane and isomers

Properties

Flame Rating
Typical Properties
ValueUnitsTest Method / Conditions
Nominal Density40kg/m³ASTM D1622/EN 1602/EN ISO 845
Compressive Strength (Parallel,23°C)0.34MpaASTM D1621/EN 826
Compressive Strength (Perpendicular,Weakest Direction,23°C)0.22MpaASTM D1621/EN 826
Tensile Strength (Parallel, Met.I,23°C)0.46MpaASTM D1623-A/EN 1607
Tensile Strength (Perpendicular,Weakest Direction,23°C)0.35MpaASTM D1623-A/EN 1607
Shear Strength (Perpendicular,weakest direction,23°C)0.202MPaASTM C273/EN 12090
Thermal Conductivity (Initial ,20°C)22mW/mKASTM C518/ASTM C177/EN 12667
Thermal Conductivity (Initial ,10°C)20.9mW/mKASTM C518/ASTM C177/EN 12667
Thermal Conductivity (Initial ,24°C)22.5mW/mKASTM C518/ASTM C177/EN 12667
Thermal Conductivity (180 Days 10°C,25 Mm Thickness Sample Aged 180 Days At 23°C, 50% R.H.)26mW/mKASTM C518/ASTM C177/EN 12667
Fire Reaction (Maximum Extent Of Burnt Length)max. 10inches (mm)EN ISO 3582
Fire Reaction (Extinguishing Time)max. 10sEN ISO 3582
Surface Burning Characteristicsmax. 25FSIASTM E84
Surface Burning Characteristicsmax. 200Smoke Dev.ASTM E84
Fire Reactionmin. 90%ASTM D3014
Fire ReactionHBFClassUL 94-Horizontal Burning
Index Of Fire5.3ClassBKZ
Leachable Chloridesmax. 20ppmASTM C871/EN 13468
Dimensional Stability {-40°F/-40°C, 7 days) - linear change (length)}±0.5%ASTM D2126/EN 1604
Dimensional Stability {+212°F/+100°C, 7 days) - Linear change (length)}1%ASTM D2126/EN 1604
Dimensional Stability {(+158°F/70°C, 97% R.H., 7 days) -Linear change (length)}1.5%ASTM D2126/EN 1604
Water Absorption By Volumemax. 0.7%ASTM D2842/EN 12087/ISO 2896
Operating Temperature-1.472°C
R-Value (180 Days,1 Inch,24°C)5.44hr·ft²·°F/BTUASTM C518/EN 12667
Closed-Cell Contentmin. 92%ASTM D6226/EN ISO 4590

Regulatory & Compliance

Certifications & Compliance

Storage & Handling

Handling Notice

Terms "parallel" and "perpendicular" are referred to slab/specimen/block thickness direction. In some applications polyurethane may present fire risks, e.g. if exposed to fire or to excessive heat in presence of oxygen or air, including when welding or cutting with torches. It is the Customer's responsibility to determine if product described herein is appropriate for Customer's purposes and end-use and to ensure that working place, storage and disposal practices are in compliance with any applicable law