company tower banner
DUNA-USA Company Logo

CORAFOAM® U 150

1 of 11 products in this brand
CORAFOAM® U 150 is used as Polyurethane rigid foam PUR. can be cut with almost any type of tool. Its closed cellular structure and absence of fibers or granular structure result in crisp, excellently defined edges after fabrication. It is also impermeable by any type of liquid, including water and solvents, making it much better suited for severe weather conditions or harsh marine environments than many other materials.

Functions: Core Material

Core Type: Polyurethane Foam

Chemical Family: Polyurethanes (PU)

Technical Data Sheet
  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Chemical Family
Composite Materials Functions

Features & Benefits

Applications & Uses

Composites End Use
Plastics & Elastomers End Uses
Blowing Agents

CFCs/HCFCs-free

Properties

Typical Properties
ValueUnitsTest Method / Conditions
Nominal Density250kg/m³ASTM D1622/EN 1602/EN ISO 845
Compressive Strength (Parallel,23°C)4.4MpaASTM D1621/EN 826
Compressive Strength (Perpendicular,Weakest Direction,23°C)4.3MpaASTM D1621/EN 826
Compressive Modulus (Parallel,23°C)130MpaASTM D1621/EN 826
Compressive Modulus (Perpendicular,Weakest Direction,23°C)125MpaASTM D1621/EN 826
Compressive Strength (Parallel,-165°C)15MpaASTM D1621/EN 826
Compressive Strength (Perpendicular,Weakest Direction,-165°C)15MpaASTM D1621/EN 826
Flexural Strength (Parallel, Met.I,23°C)6.4MpaASTM C203/EN 12089
Flexural Modulus (Parallel, Met.I,23°C)170MpaASTM C203/EN 12089
Max. Flexural Strain (Met.I,23°C)0.07LengthASTM C203/EN 12089
Heat Distortion Temperature, Met.A45 - 50°CASTM D648/EN ISO 75
Tensile Strength (Parallel, Met.I,23°C)4.3MpaASTM D1623-A/EN 1607
Tensile Strength (Perpendicular,Weakest Direction,23°C)4.2MpaASTM D1623-A/EN 1607
Tensile E-modulus (All directions,-165°C)55MpaASTM D1623-A/EN 1607
Shear Strength (Perpendicular,Weakest Direction,23°C)1.15MpaASTM C273/EN 12090
Shear Elongation At Break (Shear Strain,23°C)105%ASTM D1623/EN 1607-08
Shear Modulus(Perpendicular,23°C)13.6MpaASTM C273/EN 12090
Thermal Conductivity (Initial ,10°C)42.5mW/mKASTM C518/ASTM C177/EN 12667
Thermal Conductivity(180 Days 10°C,25 Mm Thickness Sample Aged 180 Days At 23°C, 50% R.H.)44mW/mKASTM C518/ASTM C177/EN 12667
Coefficient Of Thermal Stress Resistance (-265°F/74°F, -165°C/+23°C)min. 5CINI 2.7.01
Coefficient Of Linear Thermal Expansion (-321°F/+74°F,-196°C/+23°C)501/K·10E-6ASTM D696/EN 13471
Coefficient Of Linear Thermal Expansion Cte (+70/+120°F/+21/+48°C)601/K·10E-6ASTM D696/EN 13471
Fire ReactionB3ClassDIN 4102
Maximum Rate Of Heat Release44kWUL 1975
Leachable Chloridesmax. 60ppmASTM C871/EN 13468
Dimensional Stability (48H,-13°F/-25°C,Length/Width,Thickness)±0.5 ±0.5%ASTM D2126/EN 1604
Dimensional Stability (48H, 131°F/55°C,Amb.R.H.,Length/Width,Thickness)±0.5 ±0.5%ASTM D2126/EN 1604
Dimensional Stability (48H,158°F/70°C, Amb. R.H.,Length/Width,Thickness)±0.5 ±0.5%ASTM D2126/EN 1604
Water Absorption By Volumemax. 1%ASTM D2842/EN 12087/ISO 2896
Hardness25Shore DASTM D2240/EN ISO 868
Hardness85Shore AASTM D2240/EN ISO 868
Operating Temperature-2.5°C
R-Value (180 Days,1 Inch,24°C)3.12hr·ft²·°F/BTUASTM C518/EN 12667
Closed-Cell Contentmin. 95%ASTM D6226/EN ISO 4590
Ozone Depletion Potential (ODP)0
Global warming potential (GWP)max. 10

Storage & Handling

Handling Notice

Terms "parallel" and "perpendicular" are referred to slab/specimen/block thickness direction. In some applications polyurethane may present fire risks, e.g. if exposed to fire or to excessive heat in presence of oxygen or air, including when welding or cutting with torches. It is the Customer's responsibility to determine if product described herein is appropriate for Customer's purposes and end-use and to ensure that working place, storage and disposal practices are in compliance with any applicable law