Knowde Enhanced TDS
Identification & Functionality
- Additives Included
- Chemical Family
- Polymer Name
- Technologies
- Product Families
- Type
HFFR Polyolefin Insulation/Jacket
Features & Benefits
- Labeling Claims
Applications & Uses
- Markets
- Applications
- Cure Method
- Plastics & Elastomers End Uses
- Plastics & Elastomers Processing Methods
- Applications
- AquaGraft® 7020 is designed for use in various applications including building wire, control cables, tray cables, photovoltaic, power and telecom cable jacketing applications, and other specifications requiring superior flame, thermal, and mechanical properties. This two-component system, when blended in the appropriate ratio, will yield a finished compound which will allow the cable to pass various industry
- Applications
Control, PV, Shipboard, Telecom
Properties
- Mechanical Properties
- Thermal Properties
Value | Units | Test Method / Conditions | |
Elongation | 200 | % | — |
Specific Gravity | 1.45 | g/cm³ | — |
Tear Resistance | 43 | lbs/in | — |
Durometer (Shore A) | 98 | — | — |
Tensile Strength | 1900 | psi | — |
Value | Units | Test Method / Conditions | |
Elongation at Break (1n Oxalic Acid Solution 168 Hours at 23ºC) | 209 | % | — |
Elongation at Break (1n Oxalic Acid Solution 168 Hours at 23ºC) | 207 | % | — |
Hot Creep Elongation (15 Minutes at 150°C) | 45 | % | — |
Hot Creep Elongation (15 Minutes at 150°C) | 56 | % | — |
Hot Creep Elongation (15 Minutes at 150°C) | 36 | % | — |
Retained Elongation (7 Days in 150°C Air Oven) | 80 | % | — |
Retained Elongation (902 Oil - 4 Hours 70°C) | 99 | % | — |
Retained Tensile (1n Sodium Hydroxide Solution 168 Hours at 23ºC) | 101 | % | — |
Retained Tensile (7 Days in 150°C Air Oven) | 110 | % | — |
Retained Tensile (902 Oil - 4 Hours 70°C) | 8 | % | — |
Retained Tensile(1n Oxalic Acid Solution 168 Hours at 23ºc) | 96 | % | — |
Regulatory & Compliance
- Certifications & Compliance
- Chemical Inventories
- Quality Standards
- Specifications
When extruded and cured consistent with standard safe and acceptable wire and cable industry practices, cable insulated with AquaGraft® 7020 is designed to comply with the requirements as specified in the following standards. It is important to note that overall cable construction plays an important role in flame, fluid, and electrical performance.
IEEE 383/UL-1685
IEEE 1202 – FT2 Flame Exposure
ICEA S-73-532/ NYC Transit
TUV 2Pfg1169:2007
EN 50618:2014- Certification
- Certified Test Results including physical test data are included with each shipment.
Technical Details & Test Data
- Processing
AquaGraft® 7020 is engineered for processing on conventional extrusion equipment. It is recommended that these products be processed using a greater than 20:1 extruder with a high shear screw with adequate mixing sections. The compound supplied is in the cleanest state and is of the highest quality; however, the use of a breaker plate with a screen pack of approximately 20/20 or 20/40 mesh is recommended for optimal rheological flow and steady back pressure.
A high level of care in storage of CMB-6001 to minimize exposure to moisture is recommended to ensure that there is no degradation.
Pre-heating of the conductor may be recommended depending on cable construction and specific processing conditions.
Pre-drying of AquaGraft® 7020 is generally recommended prior to use for 4 hrs. at 150F.
The following conditions are given as a guide for processing:Temperature Profile
°F
ºC
Zone 1 (feed):
310
154
Zone 2:
320
160
Zone 3:
320
160
Zone 4:
330
165
Crosshead:
330
165
Die:
330
165
Packaging & Availability
- Packaging
- 2200 pounds (997.9 Kg) per box
- 200 pounds (90.7 Kg) per fiber drum
- PE Liners
- Use within 12 months of manufacturing date
Storage & Handling
- Storage
- A high level of care in storage to minimize exposure to moisture is recommended to ensure that there is no degradation of the CMB 6001. Once opened, CMB-6001 should be consumed immediately to avoid any premature gelling due to environmental moisture.
- Handling
- To ensure health and safety, Material Safety Data Sheets (MSDS) are available and should be consulted prior to use.