Polymer Name: Polypropylene Compound (PP Compound)

Processing Methods: Injection Molding

Fillers Included: Other Filler

Melt Flow Index: 4.0 - 4.0 g/10 min

Technical Data Sheet
  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Fillers Included
Plastics & Elastomers Functions
Technologies

Features & Benefits

Materials Features
Main Features
Detectable via metal detector, X-ray detectable

Applications & Uses

Plastics & Elastomers End Uses
Plastics & Elastomers Processing Methods

Properties

Color
Physical Form
Mechanical Properties
ValueUnitsTest Method / Conditions
Charpy Impact Strength34kJ/m2DIN EN ISO 179-1eU
Elongation at Break58%DIN EN ISO 527-1
Modulus of Elasticity (Tensile test)2300MPaDIN EN ISO 527-1
Tensile Strength25MPaDIN EN ISO 527-1
Typical Properties
ValueUnitsTest Method / Conditions
Density1.28g/cm3
Thermal Properties
ValueUnitsTest Method / Conditions
Glass Transition Temperature13°C
Melting Temperature165°CDIN 53765
Service Temperature (long term)100°C
Service Temperature (short term)130°C
Other Properties
ValueUnitsTest Method / Conditions
Melt Flow Index (230°C / 2.16 kg)4g/10 minDIN EN ISO 1133
Processing Information
Processing Parameter Value Unit
Cylinder/processing temperature 200 - 260 °C
Mold temperature 40 - 100 °C
Material temperature 230 - 250 °C
  • This material can be processed as a thermoplastic taking the normal technical provisions into account. The above mentioned information refers exclusively to the injection molding process.
  • Back pressure and injection rate should be adjusted to the component geometry accordingly. The optimum processing temperature depends upon the respective geometry of the molded part and can be different from machine to machine.
Predrying
Predrying Value Unit
Permissible residual moisture content < 0.1 %
Drying temperature 70 - 100 °C
Drying time 2 h
  • To achieve optimum mechanical properties, it is recommended to pre-dry the material w ith the above mentioned parameters.

Regulatory & Compliance

Storage & Handling

Storage & Shelf Life
The granules must be stored in dry, normally tempered rooms and in closed containers. For moisture-sensitive materials, the granules must be sealed airtight. Protection against direct sunlight must be guaranteed. The granules are usually subject to the requirements of no shelf life limitation. Shelf Life maybe limited by some additives.