Value | Units | Test Method / Conditions | |
Flexural stress at rupture perpendicular to laminations | min. 669.89 | MPa | ISO 178 |
Apparent modulus of elasticity in flexure | min. 28.216 | MPa | ISO 178 |
Compressive strength perpendicular to laminations | min. 503.49 | MPa | ISO 604 |
Impact strength (Charpy) parallel to laminations | min. 129.83 | kJ/m² | ISO 179/3C |
Tensile strength | min. 366.83 | MPa | ISO 527-4 |
Value | Units | Test Method / Conditions | |
Thermal endurance | min. 160 | T.I. | IEC 60216 |
Density | 2.074 | g/cm³ | ISO 1183 |
Water absorption, absolute | max.6.60 | mg | ISO 62 |
Value | Units | Test Method / Conditions | |
Electric strength at 90°C in oil perpendicular to laminations | min. 11.95 | kV/mm | IEC 60243-1 |
Breakdown voltage at 90°C in oil parallel to laminations | min. 75 | kV | IEC 60243-1 |
Insulation resistance after immersion in water | min. 514.000 | MOhm | IEC 60167 |
Comparative tracking index CTI | min. 600/400 | CTI | IEC 60112 |
Regulatory & Compliance
- Certifications & Compliance
- ROHS Declaration
This material does not contain any substances of very high concern as listed in the EU directive 2011/65/EU, article 4, paragraph 1