Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Polymer Name
- Technologies
- Product Families
Features & Benefits
- Materials Features
- Benefits
- Excellent Weathering Resistance
- Extreme Impact Strength
- Good Fire Rating
- Thermoformable
Applications & Uses
- Applications
- Plastics & Elastomers End Uses
- Applications
Exolon® UV is ideal for outdoor applications :
- Covered walkways and bus shelters
- Barrel vaults and skylights (also thermoformed)
Properties
- Color
- Physical Form
- Mechanical Properties
- Physical Properties
- Thermal Properties
- Typical Properties
- Electrical Properties
Value | Units | Test Method / Conditions | |
Charpy Impact Strength (23°C, 3 mm, Notched) | 80P | kg/m² | ISO 179-1eA |
Charpy Impact Strength (23°C, Unnotched) | non-break | kg/m² | ISO 179-1eU |
Flexural Modulus (2 mm/min) | 2350.0 | MPa | ISO 178 |
Flexural Strength (2 mm/min) | 90.0 | MPa | ISO 178 |
Izod Impact Strength (23°C, 3.2 mm, Notched) | 70P | kg/m² | ISO 180-A |
Nominal Strain at Break (50 mm/min) | min. 50 | % | ISO 527-1,-2 |
Tensile Modulus (1 mm/min) | 2350.0 | MPa | ISO 527-1,-2 |
Yield Strain (50 mm/min) | 6.0 | % | ISO 527-1,-2 |
Yield Stress (50 mm/min) | min. 60 | MPa | ISO 527-1,-2 |
Value | Units | Test Method / Conditions | |
Density | 1200.0 | kg/m³ | ISO 1183-1 |
Refractive Index (Procedure A) | 1.587 | - | ISO 489 |
Water Absorption Equilibrium (23°C, 50% Relative Humidity) | 0.12 | % | ISO 62 |
Water Absorption Saturation (23°C) | 0.3 | % | ISO 62 |
Value | Units | Test Method / Conditions | |
Coefficient of Linear Thermal Expansion (23 - 55°C) | 0.65 | 10⁻⁴/K | ISO 11359-1 |
Temperature of Deflection Under Load (0.45 Mpa) | 140.0 | °C | ISO 75-1, -2 |
Temperature of Deflection Under Load (1.80 Mpa) | 128.0 | °C | ISO 75-1, -2 |
Thermal Conductivity (23°C) | 0.2 | W/mK | ISO 8302 |
Vicat Softening Temperature (50 N, 50°C/h) | 148.0 | °C | ISO 306 |
Value | Units | Test Method / Conditions | |
Permanent Service Temperature (Without Load) | approx. 120 | °C | - |
Value | Units | Test Method / Conditions | |
Dissipation Factor (1 Mhz) | 95.0 | 10⁻⁴ | IEC 60250 |
Dissipation Factor (100 Hz) | 5.0 | 10⁻⁴ | IEC 60250 |
Electrical Strength (1 mm) | 34.0 | kV/mm | IEC 60243-1 |
Relative Permitivity (1 Mhz) | 3.0 | - | IEC 60250 |
Relative Permitivity (100 Hz) | 3.1 | - | IEC 60250 |
Surface Resistivity | 1e¹⁶ | Ohm | IEC 60093 |
Volume Resistivity | 1e¹⁴ | Ohm.m | IEC 60093 |
Technical Details & Test Data
- Weathering Resistance
Exolon® UV sheets show excellent weathering resistance, which guarantees their impact strength even after many years. Since their introduction in 1989, the sheets have been examined in an intensive test program, including a real-time outdoor exposure test in a southern European climate (Bandol). The sheets are provided with a 10-year warranty on unbreakability and on optical properties.
Packaging & Availability
- Available Sizes
Exolon® UV is available in thicknesses of 2 - 15 mm and in the following sizes :
Colors :- Clear 2099
- White 2130
- White 2150
- Bronze 2850
- Gray 2760
- Blue 2550
- Green 2650
Sizes (Standard) :
- 3,050 x 2,050 mm
- 6,110 x 2,050 mm