BURN BARRIER™ No. 30-30 Semi-gloss Class “A" Fire Retardant Enamel is a non-yellowing interior paint, which is recommended for use as an overcoat in areas where maximum cleansibility, durability, and fire retardancy is required. Burn Barrier™ No. 30-30 was designed as an overcoat for Burn Barrier™ No. 10-10, or it can be used as a fire resistant coating by itself on all noncombustible surfaces, where a Class “A” finish must be maintained. When applied over Burn Barrier™ No. 10-10, the durability of the coating is greatly improved.

Product Type: Enamel

Compatible Substrates & Surfaces: Wood

Features: Flame Resistant, Good Non-Yellowing Properties, High Durability, Medium Gloss

Application Method: Brush, Roller, Spray

Technical Data Sheet
  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Product Type

Features & Benefits

Applications & Uses

Application Method
Compatible Substrates & Surfaces
Surface preparation

Wood and Combustible Surfaces: New wood, fiberboard and other surfaces having uneven or excessive porosity should be scaled with Flame Control 3001 Aeryhe Promer and allowed lo dry a minimum of 16 hours belore applying BURN BARRIER™ NO. 30-30 Semi-Gloss Enamel.

Noncombustible Surfaces: Dirt, grease, oil, and other foreign matter must be removed. Dull all glossy surfaces.

Application

Stir well before using. Can be brush, spray or roller applied. If applied by spray, heavy-duty spray equipment is recommended. Thinning is not recommended; however, if desired for spray application, use only Burn Barrier™ Reducer for No. 30-30 or Odorless Mineral Spirits.

Suggested Coverage Rate

400 sq.ft./U.S. gallon [9.82 m²/L] in one or two coats.

Drying Time
  • Dries to touch: 2 - 4 hours (25°C, 50%RH)
  • Tack free: 5 - 8 hours (25°C, 50%RH)
  • Through dry: 3 - 4 days (25°C, 50%RH)

Allow at least 24 hours of drying time before recoating.

Thinners

For thinning and cleaning equipment, use Burn Barrier™ Special Reducer for No. 30-30 or odorless mineral spirits.

Technical Details & Test Data

Test Data
Coating System Details Classification/rating (When Applied to Douglas Fir)
Flame Spread (ASTM E-84) Smoke Spread (ASTM E-84)
Primer None 5 20
Base Coat  Type 30-30A applied in one coat at 400 sq. ft./U.S. gal. (9.82 m²/L) 
Top Coat None

Safety & Health

Caution

The liquid coating contains Mineral Spirits. Due care must be exercised during and after application until the coating is dry. Keep away from heat, sparks, and flame. Avoid contact with skin. Avoid breathing vapors or spray mist. Open windows and doors or use other means to ensure fresh air entry during application and drying. If you experience eye watering, headaches or dizziness, increase fresh air or wear respiratory protection (NIOSH/MSHA TC 23C or equivalent) or leave the area. Do not take it internally. Close container after each use. Use with adequate ventilation.

Packaging & Availability

Tinting

Available in white, off white, and pastel shades or may be field tinted with most universal or oil tinting colorants. Tinting colorants should not exceed 4 fluid ounces per gallon.

Packaging

Standard packaging:

  • 1 gallon cans
  • 5 gallon pails
  • 55 gallon drums