UltraPly™ TPO Flex Adhered is a flexible Thermoplastic Polyolefin roofing membrane produced with polyester weft-inserted reinforcement designed specifically for adhered installations. UltraPly TPO Flex Adhered membrane meets or exceeds all requirements for ASTM D 6878 Specification. This reflective, heat weldable TPO membrane is available in 60 mil (1.52 mm) thickness and is suitable for a variety of low-slope adhered roofing applications.

Polymer Name: Thermoplastic Polyolefin (TPO)

Physical Form: Sheets

Features: Durable, Good Weather Stability, Light Reflecting, Low Energy Consumption

End Uses: Covers, Tape

Color: White

Technical Data Sheet
  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Chemical Family
Fillers Included
Technologies

Features & Benefits

Features and Benefits
  • Wider welding window
  • Durable, strong and long lasting
  • Excellent wind up-lift resistance
  • Enhanced energy efficiency
  • Cold weather flexibility
  • High slope capabilities 

Applications & Uses

Plastics & Elastomers End Uses
Method of Application
  • Substrates must be clean, dry, smooth, and free of sharp edges, fins, loose or foreign materials, oil, grease, and other materials that may damage the membrane.
  • All roughened surfaces that can damage the membrane shall be repaired as specified to offer a smooth substrate.
  • All surface voids greater than 1⁄4" (6.3 mm) wide shall be properly filled with an acceptable fill material.
  • Firestone UltraPly TPO Flex Adhered membrane is installed as a continuous roofing or waterproofing layer on the roof. Rolls are overlapped (side and end laps) prior to heat welding of the seam areas.
  • Install the UltraPly TPO Flex Adhered Roofing System in accordance with current Firestone UltraPly TPO adhered specifications, details and workmanship requirements.

Properties

Color
Physical Form
Typical Properties
ValueUnitsTest Method / Conditions
Overall Thickness0.060 ± 10%inD 751
Coating Over Scrim0.02inD 7635
Breaking Strength220lbfD 751
Elongation of Reinforcement Break15D 751
Tearing Strengthmin. 55lbfD 751
Brittleness Point-58°FD 2137
Ozone Resistance, No CracksPassD1149
Breaking Strength (After Heat Aging ASTM D 573-5376 h (224 days or 32 weeks) at 240 °F (116 °C))min. 90%D 751
Elongation at Break (After Heat Aging ASTM D 573-5376 h (224 days or 32 weeks) at 240 °F (116 °C))min. 90%D 751
Tearing Strength (After Heat Aging ASTM D 573-5376 h (224 days or 32 weeks) at 240 °F (116 °C))min. 60%D 751
Weight of Change (After Heat Aging ASTM D 573-5376 h (224 days or 32 weeks) at 240 °F (116 °C))max. 1%
Linear Dimension Change (6 h at 158 °F (70 °C))max. 1%D 1204
Water Absorption (After Heat Aging ASTM D 573-5376 h (224 days or 32 weeks) at 240 °F (116 °C))max. 3%G 155
Weather Resistance (176 °F (80 °C) Black Panel, no cracking, crazing when wrapped around a 3" (76.2 mm) mandrel and inspected at 7X magnification)min. 60,000kJ/m2D 471
Radiative Properties
Cool Roof Rating Council (CRRC): Initial / 3 year simulated
Solar Reflectance 0.80 / 0.73
Thermal Emittance 0.90 / 0.90
Solar Reflectance Index (SRI) 100 / 90
Rated Product ID 0058
Licensed Manufacturer ID 0608
Classification Production Line

 

Packaging & Availability

Available Size

10' x 100' (3.05 m x 30.5 m)

Storage & Handling

Storage
  • Store away from sources of punctures and physical damage.
  • Assure that structural decking will support the loads incurred by material when stored on rooftop. The deck load limitations should be specified by the project designer.
  • Store away from ignition sources as membrane will burn when exposed to open flame.