company tower banner
FlameOFF Coatings Company Logo

FlameOFF® Fire Barrier paint

1 of 2 products in this brand
FlameOFF® Fire Barrier paint is a decorative, thin-film intumescent coating designed for fire protection of Gypsum/Sheetrock and Wood interior applications that require ASTM E119, ASTM E84, NFPA 251, ULC CAN S-101.

Product Type: Intumescent Coating, Waterborne Coating

Features: Cost Effective, Flame Resistant, Good Smoothness, Low VOC, Non-Toxic, UL Listed

Compatible Substrates & Surfaces: Composites, Metal, Steel, Wood

Application Method: Brush, Spray

  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Carrier
Generic Type

A water-based intumescent coating that consists of a vinyl acetate resin.

Features & Benefits

Features
  • Certified to ASTM E119/UL 263
  • Decorative esthetic coating - provides a hard, durable, architectural finish.
  • Well suited for residential and commercial applications
  • Space saving- ideal for applications when additional layers of gypsum cannot be installed
  • Compatible with most topcoats (though not required)
  • Thin film coating - offers an economical solution to alternative fireproofing
  • low VOC, LEED compliant
  • Easy repair - If damaged, product can be patched easily

Finish: Smooth
Primer: Wood: Recommended but not required
             Gypsum: Not required
            “Some tape/mud/putty products will better receive intumescent paint if first primed.
Topcoat: For interior conditioned space, topcoating is not required but may be applied for esthetic purposes.
Product must be topcoated if there are environmental exposure requirements. Refer to FlameOFF® Coatings, Inc. technical support.
Intumescent coating must be applied to the required DFT and fully cured before topcoat is applied.
Thickness Per Coat:  Recommended 20-35 Mils WFT
                                    *Range: 15-45 Mils WFT. Maximum thickness per coat depends upon applicator experience, substrate, and job site conditions.

 

Applications & Uses

Application Method
Compatible Substrates & Surfaces
Substrates & Surface Preparation

General: All surfaces must be primed and must be clean, dry, and free of oil, grease, loose scale, dirt, dust or other materials that would impair the bonding of the intumescent coating to the substrate.

Application Conditons and Curing Schedule

Application Temperature & Humidity

Condition Material Humidity
Minimum 45°F (10°C) 0%
Maximum 100°F (40°C) 85%
Temp & 50% Relative Humidity Handle Recoat
spra (spray)
Recoat
(brush)
Topcoat
70°F (21 °C) 24 Hours 7-8 hours 2-3 hours 48-72 hours

*Curing times are dependent upon temperature, ventilation, and humidity. Lower temperatures will slow down the curing process, higher temperatures will speed up the curing process. Additional ventilation (add fanmay expedite curing process. For optimum curing, itis recommended to apply coats at 20-45 mils wet per coat. Material is ready to be topcoated when an average Shore D hardness of 70 is achieved. “*See Application Guide for full application details.

Application Equipment Guidelines

General equipment guidelines are given below, and may need to be modified depending on individual jobsite conditions. See Applicatlon Gulde for full application detalls. Contact FlameOFF® Coatings with any questions.
Airless Spray: Use 1.0 gal. per minute electric airless (minimum) to provide an operating pressure of 3,000 p.s.i. (140 kg/cm2). ** Remove rock catcher from siphon tube.**
Spray Gun: Contractor Gun (with filter removed) or equivalent
Spray Tips: 0.021” - 0.025”
Fan Size: 4’-10” (depending on section being sprayed)
Hose Length: 50’ (15 m) maximum
Material Hose: 1/2” 1.D.
*™ Listed here are general equipment guidelines for the application of this product. Job site conditions may require modifications to these guidelines to achieve the desired results.**

 

Mixing & Thinning

Thinning: DO NOT THIN or alter in any way.
Mixer: Use 1/2” electric or air driven drill with a slotted paddle mixer (300 rpm under load)
Mixing: Product must be mixed using a 1/2” electric air driven drill with a slotted paddle or Jiffy mixer blade. Mix material for a minimum of 5 minutes to achieve the necessary texture required before spraying.

Application Procedures

General: Product may be applied by brush or spray application. Do not apply with a roller. Spray application is recommended for the optimum appearance.
Airless Spray: A single coat built up with a number of quick passes allows greater control over quantities, thickness and finish.
**Note - In most conditions, it is advantageous to apply two thin coats rather than one thick coat.**
Application Rates:
Spray:
20-45 Mils Wet Film Thickness
Brush: 10 Mils Wet Film Thickness
Wet Film Thickness: Frequent thickness measurements with a wet film gage are recommended during the application process to ensure uniform thickness.

Properties

Color
Properties

Solids Content: By Volume 71%
Theoretical: 1075 sq ft/gallon at 1 mil (1002 m / at 25 microns)
Coverage Rates:36 sq ft/gallon at 30 mils (3.3 2 m / at 750 microns)
VOC Values: As Supplied 0.06 Ibs/gal (7 g/l)
Flash Point: (Setaflash) 93°F (30°C)

Regulatory & Compliance

Testing / Certification

Listing This product is ICC-ES Listed and UL Classified for various applications. It has been tested at Underwriters Laboratories in accordance with ASTM E119/UL 263 Fire Endurance requirements to meet the Full Scale requirement of IBC/NFPA Building Codes.

Technical Details & Test Data

Required DFT

Required Dry Film Thickness & Corresponding Coverage Rate

  2 Hours* 1 Hour* Class A*
5/8” Type X Gypsum 45 Mils DFT 25 sq ft/gal 30Mils DFT 37 sq fl/gal
15 Mils DFT 75 sq ft/gal
1/2” Regular Gypsum x 30Mils DFT 37 sq fl/gal
15 Mils DFT 75 sq ft/gal
Wood x 30Mils DFT 37 sq fl/gal
10 Mils DFT 110 sq fi/gal

*ASTM E119 1 and 2 hour ratings
“ASTM E84 Class A flame spread and smoke development rating

Safety & Health

Cleanup & Safety

Cleanup: Flush pump, gun, tips, hoses and mixer with hot water at least once per day.
Safety: Follow all safety precautions on the product Material Safety Data Sheet.
Overspray: All adjacent and finished surfaces shall be protected from damage and overspray.

Maintenance

General: If coating becomes damaged, rebuild the required thickness by spray or brush. When dry, smooth and finished, topcoat may be applied. The repair area must follow all surface preparation requirements before reapplying the coating. The coating must be built back to the original thickness.

Packaging & Availability

Packaging Type
Packaging

5 Gal
This product is proudly manufactured in the USA
Shipping Weight: 84 Ibs per 5 gal pail

Storage & Handling

Storage and Handling

Store indoors in a dry environment between 45°F and 105°F (7°C and 40°C)
Shelf Life
12 Months
Shelf life when kept at recommended storage conditions and in original unopened containers.